Experimental Investigation of Heat Transfer and Flow Characteristics of Split Natural Cooling System for Data Center Based on Micro Heat Pipe Array

Author:

Jing Heran,Quan ZhenhuaORCID,Zhao Yaohua,Wang Lincheng,Ren Ruyang,Dong Ruixue,Wu Yuting

Abstract

This paper presents a new type of split natural cooling system that maximizes the use of natural cold energy to significantly reduce the power consumption of the air conditioning system in data centers. A split natural cooling system module, which consisted of indoor and outdoor heat exchanger based on micro heat pipe arrays connected by liquid circulation system, was selected for experimental research. The heat transfer process and flow characteristics were analyzed under different outdoor environment temperatures, air and water flow rates, and different ratios of heat transfer components (N) of indoor and outdoor heat exchangers. To improve the utilization of natural cold energy, two kinds of heat dissipation conditions, namely room and heat channel-based, were proposed. The indoor temperature of two conditions at 28 °C and 38 °C were simulated in the laboratory at constant temperature-humidity, respectively. Results indicated that the air flow rate had a greater influence on the heat transfer performance than the water flow rate. The pressure drop of the air and water sides was at a lower level, and the fitting curve of the pressure drop was obtained to provide a reference for the heat exchanger design and equipment selection. When the ratio of heat transfer components (N) of the indoor and outdoor heat exchanger was approximately 0.75, the split natural cooling system showed optimal comprehensive performance. Under heat channel-based conditions, the maximum heat transfer rate reached 12.4 kW, and the maximum energy efficiency ratio was 17.15; the maximum heat transfer rate and the maximum energy efficiency ratio increased by 42.5% and 22.64% compared with the room-based condition, respectively. The fitting curve of the energy efficiency ratio was calculated under different outdoor temperatures at two heat dissipation conditions.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3