Abstract
We recently reported that mold odor may be explained by chloroanisoles (CAs) formed by microbial biotransformation of chlorophenols (CPs) in legacy wood preservatives. Here we examine psychophysical aspects of CAs and trace their historic origins in buildings. Our exposure of healthy volunteers shows that 2,4,6-triCA is often perceived as unpleasant, characterized as musty or moldy and is detected at 13 ng/m3 or lower. Similar concentrations are reported in buildings with odor complaints. Scrutiny of written records reveal that new building construction methods were introduced in the 1950s, namely crawlspaces and concrete slabs on the ground. These constructions were prone to dampness and attack from wood decay fungi, prompting chemical companies and authorities to advocate preservatives against rot. Simultaneously, CPs became household chemicals used for example in indoor paints. When large-scale odor problems evolved, the authorities that once approved the preservatives attributed the odor to hidden mold, with no evidence that substantial microbial biomass was necessary for odor formation. Thereby the public remained unaware of problematic exposure to CPs and CAs. We conclude that the introduction of inappropriate designs of house foundations and CP-based preservatives once ignited and still provide impetus for indoor air research on “dampness and mold”.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献