Determination of Anti-Xa Inhibitor Plasma Concentrations Using a Universal Edoxaban Calibrator

Author:

Burger Annika1,Studt Jan-Dirk2,Mendez Adriana3,Alberio Lorenzo4ORCID,Fontana Pierre5ORCID,Wuillemin Walter A.6,Schmidt Adrian7,Graf Lukas8,Gerber Bernhard9ORCID,Bovet Cédric1,Sauter Thomas C.10,Binder Nikolaus B.11,Nagler Michael1ORCID

Affiliation:

1. Department of Clinical Chemistry, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland

2. Division of Medical Oncology and Hematology, University Hospital Zurich, University of Zurich, 8006 Zurich, Switzerland

3. Institute for Laboratory Medicine, Kantonsspital Aarau, 5001 Aarau, Switzerland

4. Service and Central Laboratory of Hematology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011 Lausanne, Switzerland

5. Division of Angiology and Hemostasis, Geneva University Hospital, 1205 Geneva, Switzerland

6. Division of Hematology, Hematology Laboratory, Cantonal Hospital of Lucerne, University of Bern, 3012 Bern, Switzerland

7. Institute of Laboratory Medicine, Clinic of Medical Oncology and Hematology, Municipal City Hospital Zurich Triemli, 8063 Zurich, Switzerland

8. Centre for Laboratory Medicine, 9001 St. Gallen, Switzerland

9. Clinic of Hematology, Oncology Institute of Southern Switzerland, 6500 Bellinzona, Switzerland

10. Department of Emergency Medicine, Inselspital, Bern University Hospital, 3010 Bern, Switzerland

11. Technoclone Herstellung von Diagnostika und Arzneimitteln GmbH, 1230 Vienna, Austria

Abstract

A universal calibrator for the determination of all anti-Xa inhibitors would support laboratory processes. We aimed to test the clinical performance of an anti-Xa assay utilizing a universal edoxaban calibrator to determine clinically relevant concentrations of all anti-Xa inhibitors. Following a pilot study, we enrolled 553 consecutive patients taking rivaroxaban, edoxaban, or apixaban from nine study centers in a prospective cross-sectional study. The Technochrom® anti-Xa assay was conducted using the Technoview® edoxaban calibrator. Using ultra-high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS), anti-Xa inhibitor drug concentrations were determined. Sensitivities and specificities to detect three clinically relevant drug concentrations (30 µgL−1, 50 µgL−1, 100 µgL−1) were determined. Overall, 300 patients treated with rivaroxaban, 221 with apixaban, and 32 with edoxaban were included. The overall correlation coefficient (rs) was 0.95 (95% CI 0.94, 0.96). An area under the receiver operating characteristic curve of 0.96 for 30 µgL−1, 0.98 for 50 µgL−1, and 0.99 for 100 µgL−1 was found. The sensitivities were 92.3% (95% CI 89.2, 94.6), 92.7% (89.4, 95.1), and 94.8% (91.1, 97.0), respectively (specificities 82.2%, 93.7%, and 94.4%). In conclusion, the clinical performance of a universal, edoxaban-calibrated anti-Xa assay was solid and most drug concentrations were predicted correctly.

Funder

Research Fund Haematology Cantonal Hospital Lucerne

Swiss National Science Foundation

Gottfried & Julia Bangerter-Rhyner-Stiftung

Technoclone

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3