Optimizing Image Quality with High-Resolution, Deep-Learning-Based Diffusion-Weighted Imaging in Breast Cancer Patients at 1.5 T

Author:

Olthof Susann-Cathrin1ORCID,Weiland Elisabeth2ORCID,Benkert Thomas2ORCID,Wessling Daniel3,Leyhr Daniel4ORCID,Afat Saif1ORCID,Nikolaou Konstantin15ORCID,Preibsch Heike1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany

2. MR Application Predevelopment, Siemens Healthineers AG, 91052 Erlangen, Germany

3. Department of Neuroradiology, University Hospital of Heidelberg, 69120 Heidelberg, Germany

4. Faculty of Economics and Social Sciences, Institute of Sports Science & Methods Center, University of Tuebingen, 72074 Tuebingen, Germany

5. Cluster of Excellence iFIT (EXC 2180) “Image Guided and Functionally Instructed Tumor Therapies”, University of Tuebingen, 72074 Tuebingen, Germany

Abstract

The objective of this study was to evaluate a high-resolution deep-learning (DL)-based diffusion-weighted imaging (DWI) sequence for breast magnetic resonance imaging (MRI) in comparison to a standard DWI sequence (DWIStd) at 1.5 T. It is a prospective study of 38 breast cancer patients, who were scanned with DWIStd and DWIDL. Both DWI sequences were scored for image quality, sharpness, artifacts, contrast, noise, and diagnostic confidence with a Likert-scale from 1 (non-diagnostic) to 5 (excellent). The lesion diameter was evaluated on b 800 DWI, apparent diffusion coefficient (ADC), and the second subtraction (SUB) of the contrast-enhanced T1 VIBE. SNR was also calculated. Statistics included correlation analyses and paired t-tests. High-resolution DWIDL offered significantly superior image quality, sharpness, noise, contrast, and diagnostic confidence (each p < 0.02)). Artifacts were significantly higher in DWIDL by one reader (M = 4.62 vs. 4.36 Likert scale, p < 0.01) without affecting the diagnostic confidence. SNR was higher in DWIDL for b 50 and ADC maps (each p = 0.07). Acquisition time was reduced by 22% in DWIDL. The lesion diameters in DWI b 800DL and Std and ADCDL and Std were respectively 6% lower compared to the 2nd SUB. A DL-based diffusion sequence at 1.5 T in breast MRI offers a higher resolution and a faster acquisition, including only minimally more artefacts without affecting the diagnostic confidence.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3