Abstract

Cerebrovascular disease (CVD) poses a major public health and socio-economic burden worldwide due to its high morbidity and mortality rates. Accurate assessment of cerebral arteries’ haemodynamic plays a crucial role in the diagnosis and treatment management of CVD. The study compared a non-imaging transcranial Doppler ultrasound (TCD) and transcranial color-coded Doppler ultrasound (with (cTCCD) and without (ncTCCD)) angle correction in quantifying middle cerebral arteries (MCAs) haemodynamic parameters. A cross-sectional study involving 50 healthy adults aged ≥ 18 years was conducted. The bilateral MCAs were insonated via three trans-temporal windows (TTWs—anterior, middle, and posterior) using TCD, cTCCD, and ncTCCD techniques. The MCA peak systolic velocity (PSV) and mean flow velocity (MFV) were recorded at proximal and distal imaging depths that could be visualised on TCCD with a detectable spectral waveform. A total of 152 measurements were recorded in 41 (82%) subjects with at least one-sided open TTW across the three techniques. The mean PSVs measured using TCD, ncTCCD, and cTCCD were 83 ± 18 cm/s, 81 ± 19 cm/s, and 93 ± 21 cm/s, respectively. There was no significant difference in PSV between TCD and ncTCCD (bias = 2 cm/s, p = 1.000), whereas cTCCD yielded a significantly higher PSV than TCD and ncTCCD (bias = −10 cm/s, p < 0.001; bias = −12 cm/s, p ≤ 0.001, respectively). The bias in MFV between TCD and ncTCCD techniques was (bias = −0.5 cm/s; p = 1.000), whereas cTCCD demonstrated a higher MFV compared to TCD and ncTCCD (bias = −8 cm/s, p < 0.001; bias = −8 cm/s, p ≤ 0.001, respectively). TCCD is a practically applicable imaging technique in assessing MCA blood flow velocities. cTCCD is more accurate and tends to give higher MCA blood flow velocities than non-imaging TCD and ncTCCD techniques. ncTCCD is comparable to non-imaging TCD and should be considered in clinical cases where using both TCD and TCCD measurements is needed.

Funder

Hong Kong Polytechnic University

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3