Rapid Evaluation of the Xpert® Xpress CoV-2 plus and Xpert® Xpress CoV-2/Flu/RSV plus Tests

Author:

Noble Lara DominiqueORCID,Scott Lesley Erica,Munir Riffat,Du Plessis MignonORCID,Steegen Kim,Hans LuciaORCID,Marokane Puleng,Da Silva PedroORCID,Stevens Wendy Susan

Abstract

The Xpert® Xpress SARS-CoV-2 and Xpert® Xpress SARS-CoV-2/Flu/RSV tests were rapidly developed and widely used during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. In response to emerging genetic variability, a new SARS-CoV-2 target (RNA-dependent RNA-polymerase) has been added to both tests: Xpert® Xpress CoV-2 plus and Xpert® Xpress CoV-2/Flu/RSV plus test. A rapid evaluation of both tests was performed in South Africa, using residual respiratory specimens. Residual respiratory specimens (n = 125) were used to evaluate the Xpert® Xpress CoV-2 plus test and included 50 genotyped specimens. The Xpert® Xpress CoV-2/Flu/RSV plus test was assessed using 45 genotyped SARS-CoV-2 specimens, 10 influenza A, 10 influenza B and 20 respiratory syncytial virus specimens. Results were compared to in-country standard-of-care tests. Genotyped specimens tested the performance of the test under pressure from circulating SARS-CoV-2 variants of concern. Reference material was included to assess the test limits and linearity. The Xpert® Xpress CoV-2 plus test performance compared to reference results across residual respiratory specimens was good (positive percentage agreement (PPA) = 95.2%, negative percentage agreement (NPA) = 95.0%) The Xpert® Xpress CoV-2/Flu/RSV plus test showed good performance across all residual respiratory specimens (PPA = 100%, NPA = 98.3%). All genotyped variants of concern were detected by both tests. The Xpert® Xpress CoV-2 plus and Xpert® Xpress CoV-2/Flu/RSV plus tests can be used to diagnose SARS-CoV-2, and to diagnose and differentiate SARS-CoV-2, influenza A, influenza B and respiratory syncytial virus, respectively. The NPA was lower than the recommended 99%, but was influenced by the low number of negative specimens tested. The variants of concern assessed did not affect test performance. It is recommended that sites perform their own assessments compared to in-country standard-of-care tests.

Funder

the Bill and Melinda Gates Foundation

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference45 articles.

1. A Novel Coronavirus from Patients with Pneumonia in China, 2019;Zhu;N. Engl. J. Med.,2020

2. World Health Organisation (2020, April 02). WHO Director-General’s Opening Remarks at the Media Briefing on COVID-19—11 March 2020. Available online: https://www.who.int/director-general/speeches/detail/who-director-general-s-opening-remarks-at-the-media-briefing-on-covid-19---11-march-2020.

3. United States of America Food and Drug Administation (2022, August 11). In Vitro Diagnostics EUAs—Molecular Diagnostic Tests for SARS-CoV-2, Available online: https://www.fda.gov/medical-devices/coronavirus-disease-2019-COVID-19-emergency-use-authorizations-medical-devices/in-vitro-diagnostics-euas-molecular-diagnostic-tests-SARS-CoV-2.

4. Impact of the GeneXpert MTB/RIF Technology on Tuberculosis Control;Stevens;Microbiol. Spectr.,2017

5. The Detection of SARS-CoV-2 using the Cepheid Xpert Xpress SARS-CoV-2 and Roche cobas SARS-CoV-2 Assays;Moran;J. Clin. Microbiol.,2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3