Differences in Cardiac-Pulsatility-Induced Displacement and Geometry Changes between the Cook ZBIS and Gore IBE: Postoperative Comparison Using ECG-Gated CTA Scans

Author:

Simmering Jaimy A.12,van Helvert Majorie23,van Herwaarden Joost A.4,Slump Cornelis H.5,Geelkerken Robert H.12,Reijnen Michel M. P. J.23

Affiliation:

1. Department of Surgery, Division of Vascular Surgery, Medisch Spectrum Twente, 7512 KZ Enschede, The Netherlands

2. Multi-Modality Medical Imaging (M3i) Group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, 7522 NB Enschede, The Netherlands

3. Department of Surgery, Division of Vascular Surgery, Rijnstate Hospital, 6815 AD Arnhem, The Netherlands

4. Department of Vascular Surgery, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands

5. Robotics and Mechatronics (RaM) Group, Faculty of Electrical Engineering, Mathematics and Computer Science, Technical Medical Centre, University of Twente, 7522 NB Enschede, The Netherlands

Abstract

To what extent the stentgraft design of iliac branch devices (IBDs) relates to dynamic deformation is currently unknown. Therefore, this study aimed to quantify and compare displacement and geometry changes during the cardiac cycle of two common IBDs. This paper presents a two-center trial with patients treated with a Zenith bifurcated iliac side (ZBIS) or Gore iliac branch endoprosthesis (IBE). All patients underwent a retrospective electrocardiogram (ECG)-gated computed tomographic angiography (CTA) during follow-up. Cardiac-pulsatility-induced displacement was quantified for the following locations: (neo) bifurcation of the aorta, IBD flow divider, distal markers of the internal iliac artery (IIA) component and first IIA bifurcation. Geometrical parameters (length, tortuosity index, curvature and torsion) were quantified over centerlines. Displacement was more pronounced for the IBE than the ZBIS, e.g., craniocaudal displacement of 0.91 mm (0.91–1.13 mm) vs. 0.57 mm (0.40–0.75 mm, p = 0.004), respectively. The IBDs demonstrated similar geometrical parameters in the neo-common iliac artery and distal IIA, except for the larger dynamic curvature and torsion of the distal IIA in IBEs. The IBEs showed more dynamic length and curvature change compared to the ZBIS in the stented IIA. The IIA trajectory showed more pronounced deformation during the cardiac cycle after placement of an IBE than a ZBIS, suggesting the IBE is more conformable than the ZBIS.

Funder

W. L. Gore & Associates

Health Holland

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference37 articles.

1. Endovascular Treatment of Abdominal Aortic Aneurysms;Buck;Nat. Rev. Cardiol.,2014

2. Comparison of Morphologic Features of Intact and Ruptured Aneurysms of Infrarenal Abdominal Aorta;Hinchliffe;J. Vasc. Surg.,2003

3. Long-Term Reintervention After Endovascular Abdominal Aortic Aneurysm Repair;Columbo;Ann. Surg.,2019

4. Does the Presence of an Iliac Aneurysm Affect Outcome of Endoluminal AAA Repair? An Analysis of 336 Cases;Parlani;Eur. J. Vasc. Endovasc. Surg.,2002

5. Hobo, R. (2007). Elective Endovascular Stent-Grafting of Abdominal Aortic Aneurysms, Gildeprint.