Diagnostic Accuracy of a Portable ECG Device in Rowing Athletes

Author:

Wilson FionaORCID,McHugh Cliodhna,MacManus Caroline,Baggish Aaron,Tanayan Christopher,Reddy Satyajit,Wasfy Meagan M.,Reilly Richard B.ORCID

Abstract

Background: Athletes can experience exercise-induced transient arrythmias during high-intensity exercise or competition, which are difficult to capture on traditional Holter monitors or replicate in clinical exercise testing. The aim of this study was to investigate the reliability of a portable single channel ECG sensor and data recorder (PluxECG) and to evaluate the confidence and reliability in interpretation of ECGs recorded using the PluxECG during remote rowing. Methods: This was a two-phase study on rowing athletes. Phase I assessed the accuracy and precision of heart rate (HR) using the PluxECG system compared to a reference 12-lead ECG system. Phase II evaluated the confidence and reliability in interpretation of ECGs during ergometer (ERG) and on-water (OW) rowing at moderate and high intensities. ECGs were reviewed by two expert readers for HR, rhythm, artifact and confidence in interpretation. Results: Findings from Phase I found that 91.9% of samples were within the 95% confidence interval for the instantaneous value of the changing exercising HR. The mean correlation coefficient across participants and tests was 0.9886 (σ = 0.0002, SD = 0.017) and between the two systems at elevated HR was 0.9676 (σ = 0.002, SD = 0.05). Findings from Phase II found significant differences for the presence of artifacts and confidence in interpretation in ECGs between readers’ for both intensities and testing conditions. Interpretation of ECGs for OW rowing had a lower level of reader agreement than ERG rowing for HR, rhythm, and artifact. Using consensus data between readers’ significant differences were apparent between OW and ERG rowing at high-intensity rowing for HR (p = 0.05) and artifact (p = 0.01). ECGs were deemed of moderate-low quality based on confidence in interpretation and the presence of artifacts. Conclusions: The PluxECG device records accurate and reliable HR but not ECG data during exercise in rowers. The quality of ECG tracing derived from the PluxECG device is moderate-low, therefore the confidence in ECG interpretation using the PluxECG device when recorded on open water is inadequate at this time.

Funder

Trinity College Dublin

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3