The Use of Ceus Software with No Contrast Media Administration in the Diagnosis of Pneumoperitoneum

Author:

Altiero Michele,Orabona Giuseppina Dell’AversanoORCID,Laccetti Ettore,Rengo Alessandro,Danzi Roberta,Romano FedericaORCID,Di Serafino MarcoORCID,Iacobellis FrancescaORCID,Francica Giampiero,Scaglione Mariano,Romano Luigia

Abstract

Background: Pneumoperitoneum is defined by the presence of free air in the abdominal cavity; gastrointestinal perforation is an important cause of this pathological condition. In emergency situations, radiology is considered vital in the early detection and identification of the site and cause of the perforation, which is critical for proper surgical planning. Aim: The aim of our study was to evaluate a new diagnostic US tool, based on the US contrast-specific software generally used during contrast-enhanced US examination (CEUS), without the administration of sonographic contrast media, and to describe the specific imaging features in the detection of free intra-peritoneal air. Subjects and Methods: One hundred and fifty-seven consecutive and hemodynamically stable patients, who arrived in our E.D. with an acute abdomen between April 2018 and October 2019, underwent US and CT examination, performed by three radiologists (with 5, 5, and 25 years of experience). The US was performed first and divided into two steps, using B-mode US and both B-mode and contrast-specific software US, with no contrast media administration. All the patients underwent CT examination. Results: In 32 out of 157 patients, the surgery confirmed GI perforation. CT correctly detected 31 out of 32 patients; the contrast-specific software US identified 30 perforated patients. CT reached a sensitivity value of 97% and specificity value of 100%; contrast-specific software US demonstrated higher values than B-mode US in sensitivity (93% vs. 70%, respectively) and specificity (98% vs. 88%, respectively). Conclusion: the use of contrast-specific software in emergencies improves image quality, and reaches higher levels of sensitivity and specificity with no time delay compared to standard US examination, helping radiologists expedite diagnoses.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3