Clinical Outcomes of the Intraocular Lens Injector and Busin Glide for Descemet Stripping Automated Endothelial Keratoplasty in Patients with Iridocorneal Endothelial Syndrome

Author:

Li Saiqing12,Liu Zihao12,Sun Binjia12,Zhao Zelin12,Wang Haiou12,Zheng Qinxiang12,Chen Wei12

Affiliation:

1. National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, China

2. The Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou 325027, China

Abstract

Purpose: To report the outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) performed in iridocorneal endothelial (ICE) syndrome patients using the intraocular lens injector (injector), in comparison with those using the Busin glide. Methods: In this retrospective, interventional comparative study, we evaluated the outcomes of DSAEK performed using the injector (n = 12) or the Busin glide (n = 12) for patients with ICE syndrome. Their graft position and postoperative complications were recorded. Their best-corrected visual acuity (BCVA) and endothelial cell loss (ECL) were monitored over a 12-month follow-up period. Results: DSAEK was conducted successfully in the 24 cases. The BCVA improved from the preoperative 0.99 ± 0.61 to 0.36 ± 0.35 at 12 months after operation (p < 0.001), with no significant difference between the two groups (the injector group and the Busin group) (p = 0.933). ECL at 1 month after DSAEK was 21.80 ± 15.01% in the injector group, which was significantly lower than 33.69 ± 9.75% of the Busin group (p = 0.031). No surgery-related complications were observed in the 24 cases intraoperatively or postoperatively except that one case suffered from postoperative graft dislocation, without statistical difference between the two groups. Conclusions: At 1 month after surgery, the use of graft injector for delivering DSAEK-based endothelial graft may cause significantly less endothelial cell damage than the pull-through technique used in the application of Busin glide. The injector allows safe endothelial graft delivery without the need of anterior chamber irrigation, which increases the ratio of successful graft attachment.

Funder

Chinese National Key Research and Development Project

Wenzhou Science & Technology Bureau

Publisher

MDPI AG

Subject

General Medicine

Reference36 articles.

1. Pathogenesis of Chandler’s syndrome, essential iris atrophy and the Cogan-Reese syndrome. I. Alterations of the corneal endothelium;Alvarado;Investig. Ophthalmol. Vis. Sci.,1986

2. The essential iris atrophies;Shields;Am. J. Ophthalmol.,1978

3. Progressive essential iris atrophy, Chandler’s syndrome, and the iris nevus (Cogan-Reese) syndrome: A spectrum of disease;Shields;Surv. Ophthalmol.,1979

4. Long-term surgical outcomes of patients with glaucoma secondary to the iridocorneal endothelial syndrome;Doe;Ophthalmology,2001

5. The iridocorneal endothelial syndrome;Silva;Surv. Ophthalmol.,2018

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3