Abstract
Ultrasonic flow meters (UFMs) based on transducer arrays offer several advantages. With electronic beam steering, it is possible to tune the steering angle of the beam for optimal signal-tonoise ratio (SNR) upon reception. Moreover, multiple beams can be generated to propagate through different travel paths, covering a wider section of the flow profile. Furthermore, in a clamp-on configuration, UFMs based on transducer arrays can perform self-calibration. In this manner, userinput is minimized and measurement repeatability is increased. In practice, transducer array elements may break down. This could happen due to aging, exposure to rough environments, and/or rough mechanical contact. As a consequence of inactive array elements, the measured transit time difference contains two offsets. One offset originates from non-uniform spatial sampling of the generated wavefield. Another offset originates from the ill-defined beam propagating through a travel path different from the intended one. In this paper, an algorithm is proposed that corrects for both of these offsets. The algorithm also performs a filtering operation in the frequency-wavenumber domain of all spurious (i.e., flow-insensitive) wave modes. The advantage of implementing the proposed algorithm is demonstrated on simulations and measurements, showing improved accuracy and precision of the transit time differences compared to the values obtained when the algorithm is not applied. The proposed algorithm can be implemented in both in-line and clamp-on configuration of UFMs based on transducer arrays.
Funder
Dutch Technology Foundation STW
Bronkhorst
KROHNE
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference29 articles.
1. Baker, R.C. (2005). Flow Measurement Handbook: Industrial Designs, Operating Principles, Performance, and Applications, Cambridge University Press.
2. Kang, L., Feeney, A., Su, R., Lines, D., Ramadas, S.N., Rowlands, G., and Dixon, S. (2019). Flow velocity measurement using a spatial averaging method with two-dimensional flexural ultrasonic array technology. Sensors, 19.
3. On the theory of acoustic flow measurement;Wendoloski;J. Acoust. Soc. Am.,2001
4. Lynnworth, L.C. (2013). Ultrasonic Measurements for Process Control: Theory, Techniques, Applications, Academic Press.
5. Exploiting nonlinear wave propagation to improve the precision of ultrasonic flow meters;Massaad;Ultrasonics,2021