Accuracy of Dental Implant Placement with Dynamic Navigation—Investigation of the Influence of Two Different Optical Reference Systems: A Randomized Clinical Trial

Author:

Knipper Anne1,Kuhn Katharina2ORCID,Luthardt Ralph G.2,Schnutenhaus Sigmar12ORCID

Affiliation:

1. Center for Dentistry, Dr. Schnutenhaus Community Health Center (CHC) GmbH, Breiter Wasmen 10, 78247 Hilzingen, Germany

2. Department for Dentistry, Clinic for Prosthodontics, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany

Abstract

This randomized prospective clinical study aims to analyze the differences between the computer-assisted planned implant position and the clinically realized implant position using dynamic navigation. In the randomized prospective clinical study, 30 patients were recruited, of whom 27 could receive an implant (BLT, Straumann Institut AG, Basel, Switzerland) using a dynamic computer-assisted approach. Patients with at least six teeth in their jaws to be implanted were included in the study. Digital planning was performed using cone beam tomography imaging, and the visualization of the actual situation was carried out using an intraoral scan. Two different workflows with differently prepared reference markers were performed with 15 patients per group. The actual clinically achieved implant position was recorded with scan bodies fixed to the implants and an intraoral scan. The deviations between the planned and realized implant positions were recorded using evaluation software. The clinical examinations revealed no significant differences between procedures A and B in the mesiodistal, buccolingual and apicocoronal directions. For the mean angular deviation, group B showed a significantly more accurate value of 2.7° (95% CI 1.6–3.9°) than group A, with a value of 6.3° (95% CI 4.0–8.7°). The mean 3D deviation at the implant shoulder was 2.35 mm for workflow A (95% CI 1.92–2.78 mm) and 1.62 mm for workflow B (95% CI 1.2–2.05 mm). Workflow B also showed significantly higher accuracy in this respect. Similar values were determined at the implant apex. The clinical examination shows that sufficiently accurate implant placement is possible with the dynamic navigation system used here. The use of different workflows sometimes resulted in significantly different accuracy results. The data of the present study are comparable with the published findings of other static and dynamic navigation procedures.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3