Needle-Based Electrical Impedance Imaging Technology for Needle Navigation

Author:

Liu Jan1ORCID,Atmaca Ömer12,Pott Peter Paul1ORCID

Affiliation:

1. Institute of Medical Device Technology, University of Stuttgart, 70569 Stuttgart, Germany

2. Institute of Applied Optics, University of Stuttgart, 70569 Stuttgart, Germany

Abstract

Needle insertion is a common procedure in modern healthcare practices, such as blood sampling, tissue biopsy, and cancer treatment. Various guidance systems have been developed to reduce the risk of incorrect needle positioning. While ultrasound imaging is considered the gold standard, it has limitations such as a lack of spatial resolution and subjective interpretation of 2D images. As an alternative to conventional imaging techniques, we have developed a needle-based electrical impedance imaging system. The system involves the classification of different tissue types using impedance measurements taken with a modified needle and the visualization in a MATLAB Graphical User Interface (GUI) based on the spatial sensitivity distribution of the needle. The needle was equipped with 12 stainless steel wire electrodes, and the sensitive volumes were determined using Finite Element Method (FEM) simulation. A k-Nearest Neighbors (k-NN) algorithm was used to classify different types of tissue phantoms with an average success rate of 70.56% for individual tissue phantoms. The results showed that the classification of the fat tissue phantom was the most successful (60 out of 60 attempts correct), while the success rate decreased for layered tissue structures. The measurement can be controlled in the GUI, and the identified tissues around the needle are displayed in 3D. The average latency between measurement and visualization was 112.1 ms. This work demonstrates the feasibility of using needle-based electrical impedance imaging as an alternative to conventional imaging techniques. Further improvements to the hardware and the algorithm as well as usability testing are required to evaluate the effectiveness of the needle navigation system.

Publisher

MDPI AG

Subject

Bioengineering

Reference41 articles.

1. Routine versus clinically indicated replacement of peripheral intravenous catheters: A randomised controlled equivalence trial;Rickard;Lancet,2012

2. International prevalence of the use of peripheral intravenous catheters;Alexandrou;J. Hosp. Med.,2015

3. The System Design and Evaluation of a 7-DOF Image-Guided Venipuncture Robot;Balter;IEEE Trans. Robot.,2015

4. Complications of venepuncture;Buowari;J. Adv. Biol. Biotechnol.,2013

5. Complications occurring from diagnostic venipuncture;Galena;J. Fam. Pract.,1992

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3