Qualitative Heterogeneous Signal Drop on Chemical Shift (CS) MR Imaging: Correlative Quantitative Analysis between CS Signal Intensity Index and Contrast Washout Parameters Using T1-Weighted Sequences

Author:

Stanzione ArnaldoORCID,Verde FrancescoORCID,Galatola Roberta,Romeo Valeria,Liuzzi Raffaele,Mainenti Pier Paolo,Aprea Giovanni,Klain Michele,Guadagno Elia,Del Basso De Caro Marialaura,Maurea SimoneORCID

Abstract

The aim of this study was to calculate MRI quantitative parameters extracted from chemical-shift (CS) and dynamic contrast-enhanced (DCE) T1-weighted (T1-WS) images of adrenal lesions (AL) with qualitative heterogeneous signal drop on CS T1-WS and compare them to those of AL with homogeneous or no signal drop on CS T1-WS. On 3 T MRI, 65 patients with a total of 72 AL were studied. CS images were qualitatively assessed for grouping AL as showing homogeneous (Group 1, n = 19), heterogeneous (Group 2, n = 23), and no (Group 3, n = 30) signal drop. Histopathology or follow-up data served as reference standard to classify AL. ROIs were drawn both on CS and DCE images to obtain adrenal CS signal intensity index (ASII), absolute (AWO), and relative washout (RWO) values. Quantitative parameters (QP) were compared with ANOVA analysis and post hoc Dunn’s test. The performance of QP to classify AL was assessed with receiver operating characteristic analysis. CS ASII values were significantly different among the three groups (p < 0.001) with median values of 71%, 53%, and 3%, respectively. AWO/RWO values were similar in Groups 1 (adenomas) and 2 (benign AL) but significantly (p < 0.001) lower in Group 3 (20 benign AL and 10 malignant AL). With cut-offs, respectively, of 60% (Group 1 vs. 2), 20% (Group 2 vs. 3), and 37% (Group 1 vs. 3), CS ASII showed areas under the curve of 0.85, 0.96, and 0.93 for the classification of AL, overall higher than AWO/RWO. In conclusion, AL with qualitative heterogeneous signal drop at CS represent benign AL with QP by DCE sequence similar to those of AL with homogeneous signal drop at CS, but different to those of AL with no signal drop at CS; ASII seems to be the only quantitative parameter able to differentiate AL among the three different groups.

Publisher

MDPI AG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3