Are Machine Learning Models on Wrist Accelerometry Robust against Differences in Physical Performance among Older Adults?

Author:

Bai ChenORCID,Wanigatunga Amal A.ORCID,Saldana Santiago,Casanova Ramon,Manini Todd M.,Mardini Mamoun T.ORCID

Abstract

Sufficient physical activity (PA) reduces the risk of a myriad of diseases and preserves physical capabilities in later life. While there have been significant achievements in mapping accelerations to real-life movements using machine learning (ML), errors continue to be common, particularly for wrist-worn devices. It remains unknown whether ML models are robust for estimating age-related loss of physical function. In this study, we evaluated the performance of ML models (XGBoost and LASSO) to estimate the hallmark measures of PA in low physical performance (LPP) and high physical performance (HPP) groups. Our models were built to recognize PA types and intensities, identify each individual activity, and estimate energy expenditure (EE) using wrist-worn accelerometer data (33 activities per participant) from a large sample of participants (n = 247, 57% females, aged 60+ years). Results indicated that the ML models were accurate in recognizing PA by type and intensity while also estimating EE accurately. However, the models built to recognize individual activities were less robust. Across all tasks, XGBoost outperformed LASSO. XGBoost obtained F1-Scores for sedentary (0.932 ± 0.005), locomotion (0.946 ± 0.003), lifestyle (0.927 ± 0.006), and strength flexibility exercise (0.915 ± 0.017) activity type recognition tasks. The F1-Scores for recognizing low, light, and moderate activity intensity were (0.932 ± 0.005), (0.840 ± 0.004), and (0.869 ± 0.005), respectively. The root mean square error for EE estimation was 0.836 ± 0.059 METs. There was no evidence showing that splitting the participants into the LPP and HPP groups improved the models’ performance on estimating the hallmark measures of physical activities. In conclusion, using features derived from wrist-worn accelerometer data, machine learning models can accurately recognize PA types and intensities and estimate EE for older adults with high and low physical function.

Funder

National Institute of Health

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3