Affiliation:
1. School of Engineering and Built Environment, Griffith University, Gold Coast, QLD 4215, Australia
2. Department of Agriculture and Fisheries, Queensland Government, Brisbane City, QLD 4000, Australia
3. Faculty of Society & Design, Bond University, Robina, QLD 4226, Australia
Abstract
Floor vibration, although not a safety concern, is a prevalent performance complaint in multi-story structures. With the increasing use of mass timber construction, various types of long-span timber floors (LSTFs), including plain cross-laminated timber (CLT), CLT with secondary beams (ribbed-deck), and hybrid systems such as timber–concrete composite (TCC) and CLT on-steel-support beams, are gaining popularity. However, due to limited knowledge regarding their vibration characteristics and acceptance criteria, these construction types are often overlooked during the design stage by architects, engineers, and builders. Existing standards and guidelines primarily calibrated for steel and concrete floors lack a validated and calibrated method for evaluating the vibration performance of LSTFs. Nonetheless, it is essential for structural engineers to address vibration concerns during the design stage and potentially investigate excessive vibration in existing buildings, providing mitigation solutions. This article provides a comprehensive overview, discussion, and analysis of the measurement, analysis, design, perception, and acceptability of vibration of timber floors as outlined in international standards and commonly used guidelines. Experimental and theoretical case studies, including vibration measurements of a CLT floor and a comparison of vibration acceptability in lightweight timber floors using different methods, are reported. The results highlight discrepancies between simplified equation calculations and modal analysis observations, underscoring the limitations of relying solely on simplified equations. Furthermore, it is observed that current modal superposition methods tend to be conservative in predicting floor acceleration and velocity responses. Recommendations are provided for future research in the field to enhance floor vibration assessment techniques, aiming for improved design optimization and occupant comfort.
Subject
Building and Construction,Civil and Structural Engineering,Architecture
Reference98 articles.
1. The carbon footprint of Australia’s construction sector;Yu;Procedia Eng.,2017
2. Australian Industry Skills Committee (2022). Construction, Australian Industry Skills Committee.
3. Full-scale static and dynamic experiments of hybrid CLT–concrete composite floor;Mai;Constr. Build. Mater.,2018
4. Experimental and numerical investigation of short-term behaviour of CLT-steel composite beams;Hassanieh;Eng. Struct.,2017
5. Carradine, D. (2019). Multi-Storey Light Timber-Framed Buildings in New Zealand—Engineering Design, BRANZ.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献