BIM and Computational Fluid Dynamics Analysis for Thermal Management Improvement in Data Centres

Author:

Pogorelskiy Sergey1,Kocsis Imre2ORCID

Affiliation:

1. Doctoral School of Informatics, University of Debrecen, 4032 Debrecen, Hungary

2. Department of Basic Technical Studies, Faculty of Engineering, University of Debrecen, 4032 Debrecen, Hungary

Abstract

One of the most energy-intensive facilities requiring a comprehensive and well-optimised cooling system is the data centre. Air containment across the data centre is a key thermal management and energy-saving strategy that enhances the performance of data centres. The majority of modern energy-efficient data centres use some type of air containment. The primary advantage of aisle separation and containment is the decrease in the air temperature at the server inlet by reducing the mixing of hot air with cold air. In order to ascertain the volume of literature relating to corridor insulation, we conducted a literature review. Currently, there have been numerous articles regarding the application of computational fluid dynamics (CFD) analysis, however, publications delineating the integration of building information modelling (BIM) principles for corridor separation are still limited. Research specifically targeting data centre corridor insulation is somewhat limited. As a result of this analysis, the most common methods used to isolate hot or cold aisles within a data centre were identified. To determine the most effective type of corridor insulation, the BIM family was created in Autodesk Revit. The model includes 15 telecom cabinets containing information technology (IT) equipment, eight inter-row air conditioners, and one UPS. The model was used for the CFD analysis of the air temperature in different zones of the room. Visualisation of the results using gradient temperature distributions at different levels provides a complete picture of the microclimate formation in the room and allowed the advantage of the hot aisle isolation scheme to be demonstrated.

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Reference32 articles.

1. Steve, S. (2023, August 21). The Green Grid, White Paper #50 “Data Center Efficiency and IT Equipment Reliability at Wider Operating Temperature and Humidity Ranges”. Available online: https://www.thegreengrid.org/.

2. (2023, August 21). The American Society of Heating, Refrigerating and Air-Conditioning Engineers. Available online: https://www.ashrae.org/.

3. Numerical and experimental investigations on thermal management for data center with cold aisle containment configuration;Lee;Appl. Energy,2021

4. Development and experimental study of an independent row-based cooling system for improving thermal performance of a data center;Cho;Appl. Therm. Eng.,2020

5. Optimizing energy consumption for data centers;Rong;Renew. Sustain. Energy Rev.,2016