BIM and Computational Fluid Dynamics Analysis for Thermal Management Improvement in Data Centres

Author:

Pogorelskiy Sergey1,Kocsis Imre2ORCID

Affiliation:

1. Doctoral School of Informatics, University of Debrecen, 4032 Debrecen, Hungary

2. Department of Basic Technical Studies, Faculty of Engineering, University of Debrecen, 4032 Debrecen, Hungary

Abstract

One of the most energy-intensive facilities requiring a comprehensive and well-optimised cooling system is the data centre. Air containment across the data centre is a key thermal management and energy-saving strategy that enhances the performance of data centres. The majority of modern energy-efficient data centres use some type of air containment. The primary advantage of aisle separation and containment is the decrease in the air temperature at the server inlet by reducing the mixing of hot air with cold air. In order to ascertain the volume of literature relating to corridor insulation, we conducted a literature review. Currently, there have been numerous articles regarding the application of computational fluid dynamics (CFD) analysis, however, publications delineating the integration of building information modelling (BIM) principles for corridor separation are still limited. Research specifically targeting data centre corridor insulation is somewhat limited. As a result of this analysis, the most common methods used to isolate hot or cold aisles within a data centre were identified. To determine the most effective type of corridor insulation, the BIM family was created in Autodesk Revit. The model includes 15 telecom cabinets containing information technology (IT) equipment, eight inter-row air conditioners, and one UPS. The model was used for the CFD analysis of the air temperature in different zones of the room. Visualisation of the results using gradient temperature distributions at different levels provides a complete picture of the microclimate formation in the room and allowed the advantage of the hot aisle isolation scheme to be demonstrated.

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

Reference32 articles.

1. Steve, S. (2023, August 21). The Green Grid, White Paper #50 “Data Center Efficiency and IT Equipment Reliability at Wider Operating Temperature and Humidity Ranges”. Available online: https://www.thegreengrid.org/.

2. (2023, August 21). The American Society of Heating, Refrigerating and Air-Conditioning Engineers. Available online: https://www.ashrae.org/.

3. Numerical and experimental investigations on thermal management for data center with cold aisle containment configuration;Lee;Appl. Energy,2021

4. Development and experimental study of an independent row-based cooling system for improving thermal performance of a data center;Cho;Appl. Therm. Eng.,2020

5. Optimizing energy consumption for data centers;Rong;Renew. Sustain. Energy Rev.,2016

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3