Macroscopic Mechanical Properties and Microstructure Characteristics of Solid Waste Base Capillary Retarded Field Covering Material

Author:

He Yifan12,Lu Haijun12,Lan Jirong3,Ma Jiayu1,Liu Mengyi1,Dong Yiqie1

Affiliation:

1. School of Civil Engineering and Architecture, Wuhan Polytechnic University, Wuhan 430023, China

2. State Key Laboratory of Geomechanics and Geotechnical Engineering, Institute of Rock and Soil Mechanics, Chinese Academy of Sciences, Wuhan 430071, China

3. Department of Civil and Environmental Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China

Abstract

In the practical operation of traditional landfills, compaction clay often experiences cracking, while the HDPE geomembrane may tear and bulge, resulting in a compromised performance of the landfill covering system. To address this issue, a capillary retarding covering material for landfill sites is proposed by utilizing municipal sludge and construction waste particles as substrates and incorporating a small quantity of calcium bentonite. The mechanical characteristics of the covering material were investigated using a standard consolidation test and a triaxial compression test. A permeability test and a soil water characteristic curve (SWCC) test were conducted to examine the permeability and capillary retarding effect of the covering material. Microscopic tests including SEM scanning, laser particle size analysis, and T2 NMR analysis were performed to investigate the connection mode, particle size composition, and pore structure characteristics of the covered particles. Based on the aforementioned research, the following conclusions can be drawn: The cohesion of the covering material ranged from 50 to 150 kPa, while the internal friction angle ranged from 24.23° to 31°. The cohesion was directly proportional to the content of construction waste, whereas the internal friction angle was inversely proportional to calcium bentonite content. The permeability coefficient ranged from 5.04 × 10−6 cm/s to 7.34 × 10−5 cm/s, indicating a certain level of impermeability. Both the sludge and the calcium bentonite contents jointly influenced the final permeability coefficient in a negative correlation manner, with a notable hydraulic hysteresis phenomenon observed. A higher content of construction waste leads to a more pronounced supporting force exerted by the formed skeleton structures within a load pressure range between 0 and 1600 kPa. When considering a mass ratio of municipal sludge: construction waste: calcium bentonite as 30:60:7, respectively, only a decrease in the pore ratio by approximately 13.20% was observed. This study provides valuable data support for designing and applying capillary retarding cover barrier systems in landfills.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Hubei Province of China

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3