Abstract

An important energy-saving method to optimize building envelope design is the integration of local climate characteristics. This study attempts to find sloped facade configurations to balance air conditioning energy demand and daylight utilization for four directions in an area with a hot climate. Tilt angle dependence of the air conditioning energy demand, useful daylight illuminance (UDI) and daylight glare index (DGI) are selected to investigate the acceptance thresholds of the tilt angle. The final facade’s configuration is achieved by employing the graphical optimization method. An acceptable solution that balances better daylight performance and less energy consumption by air conditioning is developed. Due to the considered city being located in a low-latitude area with great daylight availability as well as a fully dimmable light control strategy, unbearable glare reduction can be achieved by benefiting from the sloped facades, without necessarily sacrificing much usable daylight. Meanwhile, there is no obvious increase in the demand for lighting energy consumption, and a good outward view is preserved. The sloped rather than vertical facade provides natural solar shading to the east-, south- and west-oriented windows while allowing low-angle winter solar heat to warm the building space. Tilt angles between 35°and 40° are preferred for the east facade, and smaller tilt angles of between 30°and 35° are recommended for the south facade. Larger tilt angles of between 40°and 45° are preferred for the west facade. However, the north-facing facade’s outward tilt would cause an undesirable increase in air conditioning energy demand. The annual air conditioning energy demand of the east-, south- and west-facing space is found to separately decrease by 7.1%, 7.3% and 9.9%, respectively, benefiting from the sloped facades.

Funder

doctoral research start-up funding project of Guangdong Ocean University

Zhanjiang Science and Technology Project

Publisher

MDPI AG

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3