Abstract
In order to ensure the mechanical reliability of a partially encased composite wall (the PEC wall), the distribution law of the thermal residual stress of the steel bone of the PEC wall needs to be deeply studied. In this study, we first conducted a cutting thermal conductivity analysis and stress analysis of the flange and webs. Second, based on the cutting residual stress of different sheet steel, the welding thermal conductivity analysis and stress analysis of I-shaped calculation units with and without a hole in the web were carried out. Finally, the difference in the distribution of the stress on the section during welding (or cutting) and after the cooling of the welding (or cutting) was clarified, the shape and size of the residual stress distribution in the two types of steel bone formed by the cutting and welding thermal processing were evaluated, and the approximate distributions of the residual stress of the flange and webs were obtained, respectively.
Funder
National Key R&D Program of China
Subject
Building and Construction,Civil and Structural Engineering,Architecture
Reference44 articles.
1. Schleich, J.B., Lahoda, E., and Lickes, J.P. A New Technology in Fireproof Steel Construction, 1982.
2. Numerical Study and Design Recommendations of Eccentrically Loaded Partially Encased Composite Columns;Wang;Int. J. Steel Struct.,2019
3. Prickett, B.S., and Driver, R.G. Structure Engineering Report No. 262. Behaviour of Partially Encased Composite Columns Made with High Performance Concrete, 2006.
4. Test and numerical simulation of partially encased composite columns subject to axial and cyclic horizontal loads;Chen;Int. J. Steel Struct.,2010
5. Parametric study on eccentrically-loaded partially encased composite columns under major axis bending;Begum;Steel Compos. Struct.,2015
Cited by