Effects of an Innovative Head-Up Tilt Protocol on Blood Pressure and Arterial Stiffness Changes

Author:

Dorogovtsev Victor N.ORCID,Yankevich Dmitry S.ORCID,Goswami NanduORCID

Abstract

The objective of our study was to identify blood pressure (BP) and pulse wave velocity (PWV) changes during orthostatic loading, using a new the head-up tilt test (HUTT), which incorporates the usage of a standardized hydrostatic column height. Methods: 40 healthy subjects 20–32 years performed HUTT, which was standardized to a height of the hydrostatic column at 133 cm. Exposure time was 10 min in each of 3 positions: horizontal supine 1, HUTT, and horizontal supine 2. The individual tilt up angle made it possible to set the standard value of the hydrostatic column. Hemodynamic parameters were recorded beat to beat using “Task Force Monitor 3040 i”, pulse-wave velocity (PWV) was measured with a sphygmograph–sphygmomanometer VaSera VS1500N. Results: Orthostatic loading caused a significant increase in heart rate (HR) and a decrease in stroke volume (SV) (p < 0.05) but no significant reductions in cardiac output, changes in total vascular resistance (TVR), or BP. An analysis of personalized data on systolic blood pressure (SBP) changes in tilt up position as compared to horizontal position (ΔSBP) revealed non-significant changes in this index in 48% of subjects (orthostatic normotension group), in 32% there was a significant decrease in it (orthostatic hypotension group) and in 20% there was a significant increase in it (orthostatic hypertension group). These orthostatic changes were not accompanied by any clinical symptoms and/or syncope. During HUTT, all subjects had in the PWV a significant increase of approximately 27% (p < 0.001). Conclusion: The new test protocol involving HUTT standardized to a height of hydrostatic column at 133 cm causes typical hemodynamics responses during orthostatic loading. Individual analysis of the subjects revealed subclinical orthostatic disorders (OSD) in up to 52% of the test persons. During HUTT, all test subjects showed a significant increase in PWV. The new innovative HUTT protocol can be applied in multi-center studies in healthy subjects to detect preclinical forms of orthostatic disorders under standard gravity load conditions.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3