Very High-Power Short-Duration (HPSD) Ablation for Pulmonary Vein Isolation: Short and Long-Term Outcome Data

Author:

Seidl Sebastian,Mülleder Tanja,Kaiblinger Josef,Sieghartsleitner Stefan,Alibegovic-Zaborsky Jasmina,Sigmund Elisabeth,Derndorfer MichaelORCID,Kollias Georg,Pürerfellner Helmut,Martinek Martin

Abstract

Background: Circumferential pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is a standard of care intervention for patients with symptomatic atrial fibrillation (AF). During follow-up, a substantial number of patients need a redo procedure due to reconnections on the basis of insufficient non-transmural ablation lesions. High-power short-duration ablation (HPSD) is expected to create efficient lesions while causing fewer complications than in conventional RFA settings. The aim of this study was to compare one-year outcome data of very HPSD (90 Watt, 4 s) to a strategy using 50 Watt HPSD ablation guided by the CLOSE protocol using the Ablation Index (AI), an arbitrary unit composed of power, contact force and ablation time. Methods: We retrospectively analyzed short and long-term (median follow-up 23.2 ± 9.9 months) outcome data from 52 patients that were scheduled for first-do-symptomatic PVI. A very HPSD ablation protocol with 90 Watt and a 4 s duration cut-off was compared to an HPSD CLOSE approach (50 Watts; AI 550 at the anterior LA wall; AI 400 at the posterior LA wall, the roof and the floor) in terms of freedom from AF recurrence in a long-term electrocardiogram (ECG) over a five days surveillance period. To gain an impression of the subjective sense of wellbeing, the Atrial Fibrillation Effects on QualiTy-of-Life (AFEQT) score was recorded. Results: Overall freedom from AF was found in 81% (90 W 4 s) vs. 87.5% (50 W), (p = 0.52). There were 3 AF recurrences during the blanking period (90 W 4 s) vs. 1 (50 W). Within each population, one patient was scheduled for a redo-PVI-procedure. The AFEQT score was in favor of the 90 Watt 4 s approach (86.1 vs. 77.5; p = 0.37). Conclusion: Within our relatively small studied population, we found hints that in addition to shortening ablation times and radiation exposure without significantly increasing the rate of relevant intraprocedural complications, very high power short-duration ablation (90 W 4 s) provides comparable efficacy rates after one year.

Publisher

MDPI AG

Subject

Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3