Dosimetric Predictors of Toxicity after Prostate Stereotactic Body Radiotherapy: A Single-Institutional Experience of 145 Patients

Author:

Fujii Kyohei1ORCID,Nakano Masahiro2ORCID,Kawakami Shogo2,Tanaka Yuichi3ORCID,Kainuma Takuro2,Tsumura Hideyasu4,Tabata Ken-ichi4,Satoh Takefumi4,Iwamura Masatsugu4,Ishiyama Hiromichi2ORCID

Affiliation:

1. Division of Radiation Oncology, Kitasato University Hospital, 1-15-1 Kitasato, Minamiku, Sagamiharashi 252-0329, Japan

2. Department of Radiation Oncology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minamiku, Sagamiharashi 252-0329, Japan

3. Graduate School of Medical Sciences, Kitasato University, 1-15-1 Kitasato, Minamiku, Sagamiharashi 252-0329, Japan

4. Department of Urology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minamiku, Sagamiharashi 252-0329, Japan

Abstract

The indications for stereotactic body radiotherapy (SBRT) for prostate cancer have increased. However, the relationships between adverse events and risk factors remain unclear. This study aimed to clarify associations between adverse events and dose index for prostate SBRT. Participants comprised 145 patients irradiated with 32–36 Gy in 4 fractions. Radiotherapy-related risk factors such as dose-volume histogram parameters and patient-related risk factors such as T stage and Gleason score were evaluated in a competing risk analysis. Median follow-up duration was 42.9 months. A total of 9.7% had acute Grade ≥ 2 GU toxicities and 4.8% had acute Grade ≥ 2 GI toxicities. A total of 11.1% had late Grade ≥ 2 GU toxicities and 7.6% had late Grade ≥ 2 GI toxicities. Two (1.4%) patients suffered from late Grade 3 GU toxicities. Similarly, two (1.4%) patients suffered from late Grade 3 GI toxicities. Acute GU and GI events correlated with prostate volume and dose to the hottest 10 cc volume (D10cc)/volumes receiving a minimum of 30 Gy (V30 Gy) of rectum, respectively. Late GI toxicity, frequency, and rectal hemorrhage correlated with rectal D0.1 cc/D1 cc, maximum dose to the bladder, and rectal D0.1 cc, respectively. Toxicities after prostate SBRT using 32–36 Gy/4 fractions were acceptable. Our analysis showed that acute toxicities correlated with volume receiving a medium dose level, and late toxicities correlated with highest point dose of organs at risk.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3