Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt–Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study

Author:

Molinero-Mourelle PedroORCID,Cascos-Sanchez Rocio,Yilmaz Burak,Lam Walter Yu HangORCID,Pow Edmond Ho Nang,Del Río Highsmith JaimeORCID,Gómez-Polo MiguelORCID

Abstract

The aim of this in vitro study was to investigate the microgaps at the implant–abutment interface when zirconia (Zr) and CAD/CAM or cast Co–Cr abutments were used. Methods: Sixty-four conical connection implants and their abutments were divided into four groups (Co–Cr (milled, laser-sintered and castable) and Zirconia (milled)). After chewing simulation (300,000 cycles, under 200 N loads at 2 Hz at a 30° angle) and thermocycling (10,000 cycles, 5 to 50 °C, dwelling time 55 s), the implant–abutment microgap was measured 14 times at each of the four anatomical aspects on each specimen by using a scanning electron microscope (SEM). Kruskal–Wallis and pair-wise comparison were used to analyze the data (α = 0.05). Results: The SEM analysis revealed smaller microgaps with Co–Cr milled abutments (0.69–8.39 μm) followed by Zr abutments (0.12–6.57 μm), Co–Cr sintered (7.31–25.7 μm) and cast Co–Cr (1.68–85.97 μm). Statistically significant differences were found between milled and cast Co–Cr, milled and laser-sintered Co–Cr, and between Zr and cast and laser-sintered Co–Cr (p < 0.05). Conclusions: The material and the abutment fabrication technique affected the implant–abutment microgap magnitude. The Zr and the milled Co–Cr presented smaller microgaps. Although the CAD/CAM abutments presented the most favorable values, all tested groups had microgaps within a range of 10 to 150 μm.

Funder

Sociedad española de Prótesis Estomatológica y Estética

Publisher

MDPI AG

Subject

General Materials Science

Reference56 articles.

1. A systematic review of survival of single implants as presented in longitudinal studies with a follow-up of at least 10 years;Hjalmarsson;Eur. J. Oral Implantol.,2016

2. A systematic review of the survival and complication rates of zirconia‐ceramic and metal‐ceramic single crowns

3. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years

4. In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections;Sailer;Int. J. Oral Maxillofac. Implants,2009

5. Misfit of implant prostheses and its impact on clinical out-comes. Definition, assessment and a systematic review of the literature;Katsoulis;Eur. J. Oral Implantol.,2017