OnyxTMGel or Coil versus Hydrogel as Embolic Agents in Endovascular Applications: Review of the Literature and Case Series

Author:

Perri Paolo1,Sena Giuseppe2,Piro Paolo1,De Bartolo Tommaso3,Galassi Stefania3,Costa Davide4ORCID,Serra Raffaele5ORCID

Affiliation:

1. Department of Vascular and Endovascular Surgery, Annunziata Hospital, 1 Via Migliori, 87100 Cosenza, Italy

2. Department of Vascular Surgery, “Pugliese-Ciaccio” Hospital, 88100 Catanzaro, Italy

3. Departement of Interventional Radiology, Annunziata Hospital, 1 Via Migliori, 87100 Cosenza, Italy

4. Interuniversity Center of Phlebolymphology (CIFL), Magna Graecia University of Catanzaro, 88100 Catanzaro, Italy

5. Department of Medical and Surgical Sciences, Magna Graecia University of Catanzaro, 88100 Catanzaro, Italy

Abstract

This review focuses on the use of conventional gel or coil and “new” generation hydrogel used as an embolic agent in endovascular applications. In general, embolic agents have deep or multidistrict vascular penetration properties as they ensure complete occlusion of vessels by exploiting the patient’s coagulation system, which recognises them as substances foreign to the body, thus triggering the coagulation cascade. This is why they are widely used in the treatment of endovascular corrections (EV repair), arteriovenous malformations (AVM), endoleaks (E), visceral aneurysms or pseudo-aneurysms, and embolisation of pre-surgical or post-surgical (iatrogenic) lesions. Conventional gels such as Onyx or coils are now commercially available, both of which are frequently used in endovascular interventional procedures, as they are minimally invasive and have numerous advantages over conventional open repair (OR) surgery. Recently, these agents have been modified and optimised to develop new embolic substances in the form of hydrogels based on alginate, chitosan, fibroin and other polymers to ensure embolisation through phase transition phenomena. The main aim of this work was to expand on the data already known in the literature concerning the application of these devices in the endovascular field, focusing on the advantages, disadvantages and safety profiles of conventional and innovative embolic agents and also through some clinical cases reported. The clinical case series concerns the correction and exclusion of endoleak type I or type II appeared after an endovascular procedure of exclusion of aneurysmal abdominal aortic (EVAR) with a coil (coil penumbra released by a LANTERN microcatheter), the exclusion of renal arterial malformation (MAV) with a coil (penumbra coil released by a LANTERN microcatheter) and the correction of endoleak through the application of Onyx 18 in the arteries where sealing by the endoprosthesis was not guaranteed.

Publisher

MDPI AG

Reference107 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3