Abstract

The purpose of this study was to evaluate the retentive forces over time of removable partial denture clasps fabricated by the digital method. Occlusal rest seats were fabricated on three premolar teeth fixed in acrylic blocks (9 × 20 × 40 mm). Digitization of the teeth was performed using a laboratory scanner (Zirkonzahn Scanner S600 GmbH, Gais, Italy). After the analysis and determination of the insertion axis, two types of clasps with mesial occlusal rests were designed per tooth: the back-action and the reverse back-action clasps, using the Partial Planner Zirkonzahn program. The file was sent for fabrication of six metal clasps from a cobalt-chromium SP2 alloy in the EOSINT M270 system by a direct laser sintering process. The Instron 5544 universal testing machine was used to perform 20,000 cycles of clasp insertion and removal in the corresponding tooth with a load cell of 100 N and a speed of 2.5 mm/s. The retentive force was recorded for each of the 1000 cycles, and the change in retention over time was calculated. Statistical analysis was performed using the nonparametric Mann–Whitney test and a significance level of 5%. At 16,000 cycles, a maximum change in retention of 3.74 N was recorded for the back-action clasps and a minimum of −24.28 N at 1000 cycles for the reverse back-action clasps. The reverse back-action clasps exhibited statistically significant lower change in retention than the reverse-action clasps at 4000 and 5000 cycles. No differences were observed in the remaining cycles. During the 20,000 cycles, the change in retention was low regardless of the type of clasp. For most cycles, there were no differences in the change in retention between the two types of clasps.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3