Influence of Insertion Torques on the Surface Integrity in Different Dental Implants: An Ex Vivo Descriptive Study

Author:

Brancacci Erika1,García González Susana1ORCID,Galve-Huertas Andrea1ORCID,Bennani Aida2,Hernández Alfaro Federico1ORCID,Aboul-Hosn Centenero Samir1ORCID

Affiliation:

1. Department of Oral & Maxillofacial Surgery, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vàlles, Spain

2. Department of Dentistry, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallès, Spain

Abstract

Background: The primary objective of this ex vivo study was to assess the influence of increasing insertion torques on three types of dental implants and possible alterations of their microgeometry after the application of three different torque intensities. Methods: 27 implants of 3 different implant brands (Groups A, B and C) were placed in cow ribs using 30 Ncm, 45 Ncm and 55 Ncm insertion torques. The implants were subsequently removed using trephine burs, and SEM analysis was carried out in order to detect implant surface and connection changes, as compared to the implant controls. Results: Surface deformations were predominantly observed on the third apical part of the implants. The alterations presented with increasing insertion torques, with 45 Ncm being the threshold value. Prosthetic connections were also compromised. Conclusions: The changes sustained by the implants were proportional to the insertion torque they were subjected to; 45 Ncm and greater insertion torques resulted in more consistent damage, both on the implant surface and the implant connection.

Funder

Department of Oral and Maxillofacial Surgery of UIC

Publisher

MDPI AG

Subject

General Materials Science

Reference30 articles.

1. Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants;Eliasa;J. Mech. Behav. Biomed. Mater.,2012

2. On cutting torque measurements during implant placement: A 3-year clinical prospective study;Friberg;Clin. Implant. Dent. Relat. Res.,1999

3. Measurements comparing the initial stability of five designs of dental implants: A human cadaver study;Sennerby;Clin. Implant. Dent. Relat. Res.,2000

4. Correlation between placement torque and survival of single-tooth implants;Ottoni;Int. J. Oral Maxillofac. Implant.,2005

5. Implant micromotion is related to peak insertion torque and bone density;Trisi;Clin. Oral Implant. Res.,2009

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司