High-Sensitivity Slot-Loaded Microstrip Patch Antenna for Sensing Microliter-Volume Liquid Chemicals with High Relative Permittivity and High Loss Tangent

Author:

Yeo JunhoORCID,Lee Jong-Ig

Abstract

This paper proposes a microwave sensor based on a high-sensitivity slot-loaded rectangular microstrip patch antenna (MPA) for measuring microliter-volume liquid chemicals with high relative permittivity and high loss tangent. A rectangular single-ring complementary split ring resonator (SR-CSRR) slot with a bottom-edge center split (BCS) was inserted along the upper radiating edge of the patch to enhance the relative permittivity sensitivity of the MPA. The first resonant frequency of the proposed SR-CSRR-BCS slot-loaded MPA showed the highest sensitivity compared to the resonant frequencies of the MPAs with other commonly used slots for varying the relative permittivity of the planar substrate type material under test from 1 to 10 when placed above the patch. After designing the scaled SR-CSRR-BCS slot-loaded MPA with the unloaded first resonant frequency at 2.5 GHz, a hollow acrylic cylindrical liquid container with an inner volume of approximately 18.6 μL was placed at the top-edge center of the SR-CSRR-BCS slot to achieve maximum sensitivity. A quarter-wavelength transformer was applied between the patch and the feed line of the MPA to improve the impedance mismatch that occurs when liquid chemicals with a high loss tangent are placed in the container. Water, methanol, and ethanol were carefully selected for test liquids to cover a broad range of relative permittivity and high loss tangents. The proposed SR-CSRR-BCS slot-loaded MPA was designed and fabricated on a 0.76 mm-thick RF-35 substrate, and a reference RS-loaded MPA was designed and fabricated for comparison. The shift in the first resonant frequency of the input reflection coefficient characteristic was used for the sensitivity comparison, and the container was filled with 15 μL of the liquids at 25 °C. The measured sensitivity (%) of the proposed SR-CSRR-BCS slot-loaded MPA for water was 0.45%, which was higher than other antenna-based microwave sensors in the literature.

Funder

Daegu University

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3