Study on the Contamination Characteristics of V-Type Double Suspension Rod Insulators Based on the Influence of Wake Flow

Author:

Zhao ShanpengORCID,Wang TianyuORCID,Zhang Youpeng,Liu YuantaoORCID

Abstract

The insulators of the catenary of the Lanzhou-Xinjiang High-speed Railway in windy areas suffer from serious contamination, which has led to frequent flashover accidents. The catenary of the Lanzhou-Xinjiang High-speed Railway has adopted the unique external insulation of V-type double suspension rod insulators. To further determine the contamination characteristics of this type of insulator, a contamination simulation model of insulator is established in this paper based on the principles of fluid mechanics, which is used to analyze the contamination characteristics of the V-type double suspension rod insulators under the influence of wake flow. The research results show that wind speed directly determines the static pressure on the surface of the insulator, the wind speed and particle concentration are proportional to the contamination volumes on the windward and crosswind sides of insulator, while the particle size is inversely proportional to the contamination volume on the leeward side of the insulator. The direction of wake flow is consistent with the direction angle of external incoming flow, and the wake flow generating area affects the contamination characteristics of the insulator. When the incoming flow is at a prevailing wind direction of 0°, focus should be put on the windward and crosswind sides of the two insulators during insulator cleaning, and the contamination distributions on these two insulators are similar; when the incoming flow is at a prevailing wind elevation of 0°∼60°, focus should be put on the entire surface of 1# insulator and the windward and crosswind sides of 2# insulator during insulator cleaning.

Funder

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

Materials Chemistry,Surfaces, Coatings and Films,Surfaces and Interfaces

Reference31 articles.

1. The Influence of Main Components in PM2. 5 on Composite Insulator Contamination Flashover Characteristics;Liu,2014

2. A probabilistic model for insulator flashover under contaminated conditions

3. A Study on Porcelain Insulator Flashover Voltage Evaluation System on Atmospheric Pollution Condition;Gao,2014

4. Research on online diagnosis method of insulator contaminated discharge based on XGBoost algorithm;Tan,2021

5. Source strength impact analysis on polymer insulator flashover under contaminated conditions and a comparison with porcelain