Radiographic Analysis of Graft Dimensional Changes after Lateral Maxillary Sinus Augmentation with Heterologous Materials and Simultaneous Implant Placement: A Retrospective Study in 18 Patients

Author:

Comuzzi Luca,Tumedei Margherita,Piattelli Adriano,Tartaglia Gianluca,Del Fabbro MassimoORCID

Abstract

Background: This investigation aimed to radiographically assess the variations of graft dimension following maxillary sinus augmentation by the lateral approach. Methods: Eighteen patients (seven males), with a mean age at surgery of 66.5 ± 9.8 (range 52–82) years, were unilaterally treated. Thirty-five dental implants were positioned in the posterior maxilla simultaneously to grafting with heterologous biomaterials. Intraoral radiographs taken at the time of surgery, after six months, and at the longest follow-up (up to nine years after implant placement) were analyzed. The following distances were measured: mesio-distal width of the graft, vertical distance from implant apex to most coronal level of the graft, distance from the mesial aspect of the (mesial) implant to the mesial graft extension; distance from the distal aspect of the (distal) implant to the distal graft extension, and graft height along the implant axis. The dimensional changes with respect to baseline, after six months and at the longest follow-up were calculated. Results: The patient-based mean follow-up was 38.3 ± 30.1 months (range 12–108 months). The mean residual bone height at the mesial and distal aspect of the implants was 3.19 ± 2.05 mm and 2.65 ± 1.60 mm, respectively (p = 0.38). The mean graft width at baseline was 27.95 ± 5.23 mm, and the mean graft width reduction was 10.2 ± 12.7% (2.98 ± 3.62 mm) and 11.3 ± 14.4% (3.36 ± 4.08 mm) at six months and at the latest follow-up. The change was significant at six months (p = 0.005), but did not show significant further variation (p = 0.11). On the mesial and distal aspect, the mean graft extension decreased by 1.56 ± 2.67 mm and 0.84 ± 2.71 mm at the latest follow-up. No significant difference between mesial and distal changes was found (p = 0.24), suggesting that the biomaterial is resorbed homogeneously on both sides. The mean graft height was 11.92 ± 2.53 mm at baseline and decreased by 9.3 ± 9.05% (1.11 ± 1.09 mm) at six months (p < 0.001). Non-significant further changes were found at the latest follow-up (p = 0.10). Conclusions: after early remodeling, heterologous bone substitutes showed a good dimensional stability in the mid-term for maxillary sinus augmentation.

Publisher

MDPI AG

Subject

General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3