Abstract
It is well established that renewable energy resources for electricity generation are free. In hot areas, solar energy has become one of the major interests of researchers and specialists. This paper aims to experimentally investigate the maximum voltage generation of a thermoelectric generator (TEG) panel. This panel was built from many TEG modules that are connected in series and in parallel. The panel was exposed to high heat due to solar radiation during summer, either directly or through a Fresnel lens. The other side of the TEG panel was cooled using tap water that was passed through aluminum heat exchangers in an active cooling method. It was found that the maximum open-circuit voltage of this TEG panel using a Fresnel lens was 9.35 V. With no lens, it was 11.75 V at 14:00 h local time. The experiments were done during a sunny July period in Iraq.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献