Sentinel-1 Response to Canopy Moisture in Mediterranean Forests before and after Fire Events

Author:

Pirotti Francesco12ORCID,Adedipe Opeyemi1,Leblon Brigitte3

Affiliation:

1. Department of Land, Environment, Agriculture and Forestry (TESAF), University of Padua, Viale dell’Università 16, 35020 Legnaro, Italy

2. Interdepartmental Research Center of Geomatics (CIRGEO), University of Padua, Viale dell’Università 16, 35020 Legnaro, Italy

3. Faculty of Natural Resources Management, Lakehead University, Thunder Bay, ON BB 1001H, Canada

Abstract

This study investigates the sensibility of Sentinel-1 C-band backscatter to the moisture content of tree canopies over an area of about 500 km2 in north-western Portugal, with specific analysis over burnt areas. Sentinel-1 C-VV and C-VH backscatter values from 276 images acquired between January 2018 and December 2020 were assigned to five classes depending on the Drought Code (DC) scenario over several unburned and burned sites with total (>90%) forest canopy cover. Confounding variables such as tree cover and incidence angle were accounted for by masking using specific thresholds. The following results are discussed: (a) C-VV and C-VH backscatter values are inversely correlated (R2 = 0.324 to 0.438 −p < 0.001) with local incidence angle over canopies; (b) correlation is significantly stronger over very wet scenarios (DC class = 0 to 1); (c) C-VV and C-VH backscatter values can discriminate wet to dry forest environments, but they are less sensitive to the transition between dry (DC classes = 1 to 10, 10 to 100) and extremely dry environments (DC classes = 100 to 1000); (d) C-VH is more sensible than C-VV to capture burnt canopy; and (e) the C-VH polarization captures post-fire recovery after an average minimum period of 360 days after the fire event, although with less distinction for extremely wet soils. We conclude that C-band VH backscatter intensity decreases from wet to dry canopy conditions, that this behavior of the backscatter signal with respect to canopy dryness is lost after a fire event, and that after one year it is recovered.

Funder

National Research Center for Agricultural Technologies

Publisher

MDPI AG

Subject

General Earth and Planetary Sciences

Reference56 articles.

1. Fire danger rating over Mediterranean Europe based on fire radiative power derived from Meteosat;Pinto;Nat. Hazards Earth Syst. Sci.,2018

2. Pyne, S.J. (2009). Earth Observation of Wildland Fires in Mediterranean Ecosystems, Springer.

3. Gonçalves, A.C., and Sousa, A.M.O. (2017). The Fire in the Mediterranean Region: A Case Study of Forest Fires in Portugal. Mediterranean Identities—Environment, Society, Culture, InTech.

4. Van Wagner, C. (1987). Development and Structure of the Canadian Forest Fire Weather Index System, Canadian Forestry Service. Forestry Technical Report, N°35.

5. Interpreting and using outputs from the Canadian Forest Fire Danger Rating System in research applications;Wotton;Environ. Ecol. Stat.,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3