Affiliation:
1. Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy
2. Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Dental Unit, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
Abstract
This technical note aims to present a recently developed computer-guided protocol characterized by titanium-reinforced stackable surgical guides during post-extractive implant placement and subsequent immediate loading. A full maxillary edentulism was rehabilitated with one-piece implants, starting from a pre-existing removable denture. 3D digital scans of the removable denture and upper and lower arches were performed. On this basis, a prototype with ideal esthetic and functional outcomes was realized and replicated into a custom-made radiological stent with markers. The superimposition of STL and DICOM files allowed virtual planning of one-piece implants in the ideal prosthetically driven position. The stackable guides, composed of a fixed base template and additional removable components, were then realized. The fixed template, initially secured with anchor pins to the bone, was no longer removed. The removable components, which were screwed to the base template, were used to perform implant surgery and immediate prosthetic loading. No surgical complications occurred, the implants achieved a minimum insertion torque of 35 Ncm, and immediate prosthetic loading was performed. The base template allowed for the maintenance of a fixed reference during the entire workflow, improving the transition between the digital project, the surgical procedure, and the prosthetic rehabilitation.
Funder
Italian Ministry of Health—current research IRCCS
Reference34 articles.
1. A completely digital workflow for the transition from a failed dentition to interim complete-arch fixed implant-supported prostheses: A clinical report;Negreiros;J. Prosthet. Dent.,2022
2. Computer-assisted planning of oral implant surgery: A three-dimensional approach;Verstreken;Int. J. Oral Maxillofac. Implant.,1996
3. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible;Hermann;J. Periodontol. 2000,2001
4. Aesthetics and implant dentistry;Tarnow;Periodontology 2000,1996
5. Advantages and disadvantages of implant navigation surgery. A systematic review;Barootchi;Ann. Anat.,2019
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献