Abstract
In general, the lateral confinement capacity of RC columns is influenced by the strength and configuration of transverse reinforcement. In this study, performed antisymmetric flexural moment experiments that simulated seismic loads, with the configuration and yield strength of the transverse reinforcement of RC square columns as main variables. The eight specimens were square cross-sections measuring 250 × 250 mm, and the lateral confinement effect in relation to main variables was examined by inducing flexural failure in the plastic hinge zone under a shear span-to-depth ratio (a/D) of 3.0. Transverse reinforcements comprised a square and octagonal S-series and tie-based H-series. The yield strengths of the transverse reinforcements were 453 MPa and 1053 MPa, respectively. Compared to the H-series, the S-series, whose configuration of transverse reinforcement is closer to a circular form, exhibited more prominent ductile behavior after flexural yield with increasing yield strength of transverse reinforcement, which indicates greater lateral confinement.