Performance Study of Portable Semiconductor Refrigeration Device Based on CFD Simulation

Author:

Li Bin1,Wang Feng2,Jiang Feng1ORCID,Zhao Shaocong3,Wei Shutao4,Peng Piaolin2,Wang Xiangdong5,Jiang Anna6

Affiliation:

1. Institute of Manufacturing Engineering, Huaqiao University, Xiamen 361021, China

2. College of New Materials and Footwear Engineering, Liming Vocational University, Quanzhou 362000, China

3. P. E. Department, Xiamen University of Technology, Xiamen 361000, China

4. Innovation and Research Center, 361° (CHINA) Co., Ltd., Xiamen 361000, China

5. School of Physical Education, Jimei University, Xiamen 361021, China

6. College of Mechanical Engineering and Automation, Huaqiao University, Xiamen 361021, China

Abstract

Since the summer of 2022, the whole world has suffered the abnormal weather phenomena of high ambient temperature. Equipment for refrigeration, particularly portable refrigeration equipment, is crucial for personal protection in high–temperature environments, but cooling performance and miniaturization have been challenging issues. A portable air conditioner based on a semiconductor refrigeration device for human body cooling was developed. The total weight of the device is 450 g. The overall power consumption of the device is 82 W and the energy consumption ratio of semiconductor cooling plate is 0.85. The semiconductor refrigeration technology is based on the Peltier effect, supplemented by a DC fan to send the cooling air out to a specified position or zone. The structural parts are manufactured by 3D printing technology to make the overall size of the device more compact. The air volume and cooling performance of the device were analyzed by computational fluid dynamics simulation and the temperature distribution was measured by an infrared thermal imager and other instruments, and the measured results agreed with the CFD simulation results. The test ambient temperature was 20 °C. The measurement results showed that the wind speed of the hot air outlet was 6.92 m/s and that of the cold air outlet was 8.24 m/s. The cold air surface temperature reached a stable state of 13.9 °C in about 4 min, while the hot air surface temperature reached a stable state of 47.2 °C.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3