Cup-To-Neck Contact and Range of Motion after Total Hip Arthroplasty with Large Head Diameters: An Original Three-Dimensional Combined Gait and Videofluoroscopy Analysis

Author:

Belvedere ClaudioORCID,Lullini Giada,Ortolani MaurizioORCID,Ensini Andrea,Durante Stefano,Ruberto FrancescoORCID,Turner Emma,Leardini AlbertoORCID

Abstract

After a total hip arthroplasty, a limited range of motion and lower-limb disability continue to be observed, with these being mainly associated with the implant design and the head-to-neck ratio. Larger diameters of the head bearings were assumed to provide better stability, a larger range of motion, and smaller risks of dislocation and stem-to-liner impingement. However, these claims have never been demonstrated in real patients. The specific aim of this study was to assess, via multi-instrumental analysis, whether the range of motion of a replaced hip is limited by the stem-to-liner contact in patients with large femoral head diameters. Twenty-three patients with a total hip arthroplasty were evaluated at their one-year follow-ups using clinical and instrumental examinations. A combined three-dimensional gait analysis of the full body and videofluoroscopy analysis of the replaced hip were performed during the execution of standard, i.e., daily living, and more demanding motor tasks. The latter were meant to reach the extreme range of motion at the replaced hip site, thus revealing possible stem-to-liner contact. An original technique based on imaging and computer-aided design (CAD) models of the prosthesis components was developed to calculate the stem-to-liner distance. Excellent clinical scores were observed in the study. The gait analysis showed that the range of motion of the replaced hip in the sagittal plane, averaged over all patients, ranged from 28° to 78° in standard activities. In more demanding tasks, single peaks were as high as 110°, 39°, and 60° in the sagittal, frontal, and transverse anatomical planes, respectively. In all motor tasks, the stem-to-liner distances ranged from 8.7 to 13.0 mm on average, with one outlier minimum distance being 2.2 mm. This study shows that, even in demanding motor tasks and with an extreme range of motion, the hip joint replaced with large femoral head diameters did not experience impingement between the prosthesis components.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3