Design-Dependent Electrophysiological Effects of Electrolysis Electrodes Used for Endodontic Disinfection

Author:

Bauer Reinhard1ORCID,Ringel Johannes2ORCID,Koch Maximilian3ORCID,Laschke Matthias W.4ORCID,Burkovski Andreas3ORCID,Karl Matthias5ORCID

Affiliation:

1. Institute for Molecular Cell Biology, University Hospital Jena, Friedrich-Schiller University of Jena, 07745 Jena, Germany

2. Institute of Microwaves and Photonics, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany

3. Division of Microbiology, Department of Biology, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany

4. Institute for Clinical and Experimental Surgery, Saarland University, 66424 Homburg, Germany

5. Department of Prosthodontics, Saarland University, 66424 Homburg, Germany

Abstract

Electrochemical disinfection in dentistry using boron-doped diamond (BDD) electrodes bears the potential risk of disturbing vital functions. Applying different arrays of BDD electrodes and an electrotome as reference, it was the goal of this animal study to compare their effects on an electrocorticogram (ECoG) and electrocardiogram (ECG). Following the trepanation of teeth in rats, the electrodes and electrotome were applied in a randomized manner while recording ECoG and ECG. The recordings were classified according to an electrophysiological significance score based on involvement, extent of disruption and duration. The scores obtained were compared by means of ANOVA followed by Dunn’s multiple comparisons test (α = 0.05). Voltage type and electrode design had a significant influence on the detectable electrophysiological effects. The results seen with BDD electrodes ranged from no detectable electrophysiological effects to a pronounced effect. The application of the electrotome induced the most pronounced effects. Given that electrotomes are safe medical devices, despite evoking greater disturbance compared to BDD electrodes, regardless of their design, electrochemical disinfection may be considered a safe procedure.

Publisher

MDPI AG

Reference43 articles.

1. Böhm, A.L., Koch, M., Rosiwal, S., Burkovski, A., Karl, M., and Grobecker-Karl, T. (2019). Electrochemical Disinfection of Experimentally Infected Teeth by Boron-Doped Diamond Electrode Treatment. J. Clin. Med., 8.

2. Koch, M., Palarie, V., Koch, L., Burkovski, A., Zulla, M., Rosiwal, S., and Karl, M. (2022). Preclinical Testing of Boron-Doped Diamond Electrodes for Root Canal Disinfection-A Series of Preliminary Studies. Microorganisms, 10.

3. Electrochemical preparation and treatment of the root canals using depotphoresis materials as galvanic post elements;Enginalev;ZWR,1985

4. Simulation studies on depot iontophoresis;Knappwost;Dtsch. Zahnarztl. Z.,1977

5. New developments in depot inotophoresis of copper compounds;Knappwost;Dtsch. Zahnarztl. Z.,1977

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3