The fire behavior of polymers is examined primarily with the time-dependent heat release rate (HRR) measured with a cone calorimeter. The HRR is used to examine the fire behavior of materials with and without flame retardants, especially Polypropylene (PP-Copo) and Polyethylene (PE-LD). Polypropylene is stored for up to 99 days under normal conditions and the heat release rate shows especially changes about 100 s after irradiation with cone calorimeter, which may be caused by aging effects. The effect of crosslinking to the burning behavior of PP was examined too. Polyamides (PA 6) are irradiated with a radiation intensity of 25 kW/m2 to 95 kW/m2 and fire-related principles between radiation intensity and time to ignition can be derived from the measurement results. In order to comprehensively investigate the fire behavior of PP (also with flame retardant additives), the samples were also exposed to a flame, according to UL 94 with small power (50 W) and is inflamed with the power of a few 100 W. The irradiation causes different trigger mechanisms for the flame retardant additives in a plastic than the flame exposure. It is shown that the compound, which is favorable for irradiation, is not necessarily good for flame exposure. It can be seen that expandable graphite alone or with the addition of other additives is a very effective flame retardant for PP.
Subject
General Materials Science
Reference40 articles.
1. ISO 5660-1. Reaction-to-Fire Tests—Heat Release, Smoke Production and Mass Loss Rate—Part 1: Heat Release Rate (Cone Calorimeter Method) and Smoke Production Rate (Dynamic Measurement)shop.austrian-standards.at/action/de/public/details/661613/ISO_5660-1_A1_2019_08_15
2. POST-CRYSTALLIZATION AND PHYSICAL AGING OF POLYPROPYLENE: MATERIAL AND PROCESSING EFFECTS
3. Ageing of polypropylene: processes and consequences
4. Plastics Flamability Handbook;Troitzsch,2004
5. Experience Gained of Fire Tests According EN 45 545-2 and DIN 5510-2 for Seats; Fire Safety in Railway Systems 2015;Hohenwarter,2015
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献