The Comparison Features of ECG Signal with Different Sampling Frequencies and Filter Methods for Real-Time Measurement

Author:

Bui Ngoc-Thang,Byun Gyung-su

Abstract

Electrocardiogram (ECG) signals have been used to monitor and diagnose signs of cardiovascular disease and abnormal signals about the human body. ECG signals are typically characterized by the PR, QRS, QT interval, ST-segment, and heart rate (HR) parameters. ECG devices are widely used for many applications, especially for the elderly. However, ECG signals are often affected by noises from the environment. There are mainly two types of noises that affect the ECG signals: low frequencies from muscle activity and 50/60 Hz from the electrical grid. Removing these noises is important for improving the quality of the ECG signal. A clear ECG signal makes it easy to diagnose cardiovascular problems. ECG signals with high sampling frequency are more accurate. However, the noises in the signal will be more obvious and it will be difficult to remove these noises with filters. We analyzed the symmetrical correlation between the sampling frequency of the signal and the parameters of the signal such as signal to noise ratio (SNR) and signal amplitude. This study will compare characterization of ECG signals performed at different sampling frequencies before and after applying infinite impulse response (IIR) and symmetric finite impulse response (FIR) filters. Therefore, it is critical that the sampling frequency is consistent at the same frequency of the ECG signal for accurate diagnosis. Furthermore, the approach can be also important for the device to help reduce the device’s computing power and hardware resources. Our results were tested with the MIT/ BIH database at 360 Hz sampling frequency with 11-bit resolution. We also experimented with the device operating in real-time with a sampling frequency from 100 Hz to 2133 Hz and a 24-bit resolution. The test results show the advantages of the symmetric FIR filter over IIR when applied to the filtering of ECG signals. The study’s conclusions can be applied to real-world devices to improve the quality of ECG signals.

Funder

Inha University Research Grant under Grant INHA-00000

Publisher

MDPI AG

Subject

Physics and Astronomy (miscellaneous),General Mathematics,Chemistry (miscellaneous),Computer Science (miscellaneous)

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3