Abstract
The increasing use of biomass combustion systems as household appliances for heat generation is causing concern about local air quality. Areas with high concentrations of particulate matter (PM) emissions are linked to health risks. There is a need for a removal device that collects the particles before they reach the atmosphere. Electrostatic precipitators (ESPs) are the most suitable option. In this study, a laboratory-scale prototype ESP was tested with a pellet boiler. Retention efficiencies above 90% were obtained with three different discharge electrode dispositions. The continuous operation of the ESP was achieved with a dynamic control system despite fluctuations in emissions, gas conditions, etc. The accumulation of particles on inner ESP surfaces over the operation time reduced the effectiveness of the electric field, and thus retention efficiency. In this study, the retention efficiency fell from 90% to 31% in 34 h.
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献