Evaluation of the Water Sorption and Solubility Behavior of Different Polymeric Luting Materials

Author:

Labban Nawaf,AlSheikh RashaORCID,Lund Melvin,Matis Bruce A.,Moore B. Keith,Cochran Michael A.,Platt Jeffrey A.

Abstract

Objective: The study evaluated the water sorption (WSP) and water solubility (WSL) characteristics of different luting agents over a 180-day water storage period. Materials and Methods: Nine luting materials, i.e., conventional resin cement: Panavia F (PF), Rely X ARC (RA), self-adhesive resin cement: Rely X Unicem (RU), Breez (BZ), Maxcem Elite (MX), BisCem (BC) and resin-modified glass ionomer cement: FujiCem (FC), FujiPlus (FP) Rely X luting plus (RL) were assessed and fifty-two-disc specimens of each material were fabricated. All specimens were desiccated until a constant weight (W0) was reached. Thirteen specimens for each luting material were then randomly assigned to one of the four water immersion periods (7, 30, 90, and 180 days). After each period, the specimens were removed from the water and weighed to get W1. The samples were again desiccated for a second time and W2 was measured. Both WSP and WSL were determined by the following equations: WSP (%) = (W1 − W2) × 100/W0 and WSL (%) = (W0 − W2) × 100/W0. Assessments were performed following ISO standards. ANOVA was used to assess the effect of luting agent and time period on water sorption and solubility. Pair-wise comparisons were adjusted using Tukey’s multiple comparison procedure. A significance level of 0.05 was used for all statistical tests. Results: The highest mean WSP and WSL (WSP/WSL) were demonstrated by resin-modified glass-ionomers (RL 18.32/3.25, FC 17.08/4.83, and FP 14.14/1.99), while resin luting agents showed lower WSP and WSL results (PF 1.6/0.67 and RA 1.76/0.46), respectively. The self-adhesive agents exhibited a wide range of WSP and WSL values (RU 1.86/0.13, BZ 4.66/0.93, and MX 3.68/1.11). Self-adhesive cement showed lower WSP and WSL compared with the resin-modified glass-ionomers (p < 0.05). All the materials reached equilibrium after 90-days. Conclusions: Resin-based luting materials have the lowest sorption and solubility. Rely X Unicem self-adhesive luting materials were comparable to resin luting materials for WSL and WSP. Resin-modified glass-ionomer showed the highest water sorption and solubility compared with both resin and self-adhesive materials.

Publisher

MDPI AG

Subject

Polymers and Plastics,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3