Remote Measurements of Tear Electrolyte Concentrations on Both Sides of an Inserted Contact Lens

Author:

Lakowicz Joseph R.1,Badugu Ramachandram1,Sivashanmugan Kundan1,Reece Albert12

Affiliation:

1. Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, Baltimore, MD 21201, USA

2. Department of Obstetrics, Gynecology and Reproductive Sciences, University of Maryland School of Medicine, 655 W. Baltimore St., Baltimore, MD 21201, USA

Abstract

In this paper, a method is described to perform ion concentration measurements on both sides of an inserted contact lens, without physical contact with the eye or the contact lens. The outer surface of an eye is covered with a tear film that has multiple layers. The central aqueous layer contains electrolytes and proteins. When a contact lens is inserted, it becomes localized in the central layer, which creates two layers known as the pre-lens tear film (PLTF) and the post-lens tear film (PoLTF). The PoLTF is in direct contact with the sensitive corneal epithelial cells which control electrolyte concentrations in tears. It is difficult to measure the overall electrolyte concentration in tears because of the small 7 μL volume of bulk tears. No methods are known, and no method has been proposed, to selectively measure the concentrations of electrolytes in the smaller volumes of the PLTF and the PoLTF. In this paper, we demonstrate the ability to localize fluorophores on each side of a contact lens without probe mixing or diffusion across the lens. We measured the concentration of sodium in the region of the PoLTF using a sodium-sensitive fluorophore positioned on the inner surface of a contact lens. The fluorescence measurements do not require physical contact and are mostly independent of eye motion and fluorophore concentration. The method is generic and can be combined with ion-sensitive fluorophores for the other electrolytes in tears. Instrumentation for non-contact measurements is likely to be inexpensive with modern opto-electronic devices. We expect these lenses to be used for measurements of other ions in the PLTF and the PoLTF, and thus become useful for both research and in the diagnosis of infections, keratitis and biomarkers for diseases.

Funder

National Institutes of General Medical Sciences

Publisher

MDPI AG

Subject

Physical and Theoretical Chemistry,Analytical Chemistry

Reference64 articles.

1. Diagnosis and management of neurotrophic keratitis;Sacchetti;Clin. Ophthal.,2014

2. Microbial flora in eyes of current and former contact lens wearers;Fleiszig;J. Clin. Micro.,1992

3. Risk factors for microbial keratitis with contemporary contact lenses;Dart;Ophthalmology,2008

4. The incidence of contact-lens related microbial keratitis in Australia;Stapleton;Ophthalmology,2008

5. Incidence of contact-lens-associated microbial keratitis and its related morbidity;Cheng;Lancet,1999