Batch-Injection Amperometric Determination of Glucose Using a NiFe2O4/Carbon Nanotube Composite Enzymeless Sensor

Author:

Nascimento Amanda B.1,de Faria Lucas V.12,Matias Tiago A.13,Lopes Osmando F.1ORCID,Muñoz Rodrigo A. A.1ORCID

Affiliation:

1. Institute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-902, MG, Brazil

2. Institute of Chemistry, Department of Analytical Chemistry, Fluminense Federal University, Niteroi 24020-141, RJ, Brazil

3. Chemistry Department, Federal University of Espírito Santo—UFES, Vitória 29075-910, ES, Brazil

Abstract

The development of sensitive and selective analytical devices for monitoring glucose levels (GLU) in biological fluids is extremely important for clinical diagnostics. In this work, we produced a new composite based on NiFe2O4 and multi-walled carbon nanotubes (MWCNT), called NiFe2O4@MWCNT, to be applied as a non-enzymatic amperometric sensor for GLU. Both NiFe2O4 and NiFe2O4@MWCNT composites were properly characterized by XRD, SEM, FTIR, and Raman spectroscopy, which confirmed that the composite was successfully prepared. A glassy-carbon electrode (GCE) modified with NiFe2O4@MWCNT was investigated by cyclic voltammetry and applied for the amperometric GLU detection using batch-injection analysis (BIA). A linear working range between 50 and 600 µmol L−1 GLU with a significant increase in sensitivity (3-fold) in comparison with MWCNT/GCE was verified, with a detection limit of 36 µmol L−1. Inter-electrode measurements (n = 4, RSD = 10%) indicated that the sensor fabrication is reproducible. Furthermore, the proposed non-enzymatic sensor was selective even in the presence of other biomarkers found in urine. When applied to synthetic urine samples, recovery levels between 84 and 95% confirmed analytical accuracy and the absence of sample matrix effect. Importantly, the developed approach is simple (free of biological modifiers), fast (77 injections per hour), and practical (high-performance tool), which are suitable features for routine analyses.

Funder

FAPEMIG

CNPq

CAPES

INCTBio

Publisher

MDPI AG

Reference74 articles.

1. Modification of Multi-Walled Carbon Nanotubes Composite Paste Electrode with Nanonickel Pentacyanonitrosylferrate and Nickel Oxide Nanoparticles for Non-Enzymatic Glucose Determination;Hasanzadeh;Iran. Chem. Soc. Anal. Bioanal. Chem. Res.,2023

2. New Colorimetric Detection of Glucose by Means of Electron-Accepting Indicators: Ligand Substitution of [Fe(Acac)3−n(Phen)n]n+ Complexes Triggered by Electron Transfer from Glucose Oxidase;Morikawa;Chem. A Eur. J.,2002

3. One-Pot Preparation of NiMn Layered Double Hydroxide-MOF Material for Highly Sensitive Electrochemical Sensing of Glucose;Wei;J. Electroanal. Chem.,2023

4. Non-Enzymatic Electrochemical Sensing of Glucose;Wang;Microchim. Acta,2013

5. NiFe2O4/CNTs Fabricated by Atomic Layer Deposition as Highly Stable Peroxidase Mimics for Sensitive Colorimetric Detection of Hydrogen Peroxide and Glucose;Wu;Mater. Res. Bull.,2022