Sugars’ Quantifications Using a Potentiometric Electronic Tongue with Cross-Selective Sensors: Influence of an Ionic Background

Author:

Arca ,Peres ,Machado ,Bona ,Dias

Abstract

Glucose, fructose and sucrose are sugars with known physiological effects, and their consumption has impact on the human health, also having an important effect on food sensory attributes. The analytical methods routinely used for identification and quantification of sugars in foods, like liquid chromatography and visible spectrophotometry have several disadvantages, like longer analysis times, high consumption of chemicals and the need for pretreatments of samples. To overcome these drawbacks, in this work, a potentiometric electronic tongue built with two identical multi-sensor systems of 20 cross-selectivity polymeric sensors, coupled with multivariate calibration with feature selection (a simulated annealing algorithm) was applied to quantify glucose, fructose and sucrose, and the total content of sugars as well. Standard solutions of ternary mixtures of the three sugars were used for multivariate calibration purposes, according to an orthogonal experimental design (multilevel fractional factorial design) with or without ionic background (KCl solution). The quantitative models’ predictive performance was evaluated by cross-validation with K-folds (internal validation) using selected data for training (selected with the K-means algorithm) and by external validation using test data. Overall, satisfactory predictive quantifications were achieved for all sugars and total sugar content based on subsets comprising 16 or 17 sensors. The test data allowed us to compare models’ predictions values and the respective sugar experimental values, showing slopes varying between 0.95 and 1.03, intercept values statistically equal to zero (p-value ≥ 0.05) and determination coefficients equal to or greater than 0.986. No significant differences were found between the predictive performances for the quantification of sugars using synthetic solutions with or without KCl (1 mol L−1), although the adjustment of the ionic background allowed a better homogenization of the solution’s matrix and probably contributed to an enhanced confidence in the analytical work across all of the calibration working range.

Publisher

MDPI AG

Subject

Physical and Theoretical Chemistry,Analytical Chemistry

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3