Abstract
In this paper, the simulation software EBSILON is used to simulate the reheat units, and the reheat temperature control mode is deeply explored. In the benchmark system, the influence of different load intermediate point temperature on the flue gas recirculation (FGR) is analyzed. Then, the effects of load, coal quality, excess air factor, and feed water temperature on FGR are studied under the premise of intermediate point temperature as design value, and the cause for FGR change is analyzed by comparing the cutoff bypass flue (CBF) system. The results show that under any load, the FGR decreases with the increase of the intermediate point temperature, while under low load, the change of the intermediate point temperature has a greater impact on the FGR rate. When the intermediate point temperature remains constant, the FGR plunge has an increase of load at low load and is almost unchanged at high load; the FGR rate of coal with low calorific value and high moisture content is low and the coal with low volatile and high ash content has great influence on reheat steam temperature; and the excess air factor and feed water temperature are inversely proportional to the flue gas recirculation rate. In the CBF system, the change trend is similar to the reference system, but under the same working condition, the FGR rate is higher than the latter.
Funder
Key Technology Research and Development Program of Shandong
Natural Science Foundation of Shandong Province
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献