Quantifiable Measures of Abdominal Wall Motion for Quality Assessment of Cine-MRI Slices in Detection of Abdominal Adhesions

Author:

van den Beukel Bastiaan A. W.1ORCID,de Wilde Bram2ORCID,Joosten Frank3,van Goor Harry1ORCID,Venderink Wulphert2,Huisman Henkjan J.2ORCID,ten Broek Richard P. G.1ORCID

Affiliation:

1. Department of Surgery, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands

2. Department of Radiology and Nuclear Medicine, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands

3. Department of Radiology and Nuclear Medicine, Hospital Rijnstate Arnhem, 6815 AD Arnhem, The Netherlands

Abstract

Abdominal adhesions present a diagnostic challenge, and classic imaging modalities can miss their presence. Cine-MRI, which records visceral sliding during patient-controlled breathing, has proven useful in detecting and mapping adhesions. However, patient movements can affect the accuracy of these images, despite there being no standardized algorithm for defining sufficiently high-quality images. This study aims to develop a biomarker for patient movements and determine which patient-related factors influence movement during cine-MRI. Included patients underwent cine-MRI to detect adhesions for chronic abdominal complaints, data were collected from electronic patient files and radiologic reports. Ninety slices of cine-MRI were assessed for quality, using a five-point scale to quantify amplitude, frequency, and slope, from which an image-processing algorithm was developed. The biomarkers closely correlated with qualitative assessments, with an amplitude of 6.5 mm used to distinguish between sufficient and insufficient-quality slices. In multivariable analysis, the amplitude of movement was influenced by age, sex, length, and the presence of a stoma. Unfortunately, no factor was changeable. Strategies for mitigating their impact may be challenging. This study highlights the utility of the developed biomarker in evaluating image quality and providing useful feedback for clinicians. Future studies could improve diagnostic quality by implementing automated quality criteria during cine-MRI.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Computer Graphics and Computer-Aided Design,Computer Vision and Pattern Recognition,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3