Denoising of Optical Coherence Tomography Images in Ophthalmology Using Deep Learning: A Systematic Review

Author:

Ahmed Hanya1ORCID,Zhang Qianni1ORCID,Donnan Robert2,Alomainy Akram1

Affiliation:

1. Department of Electronic Engineering and Computer Science, Queen Mary University of London, London E1 4NS, UK

2. Department of Engineering and Materials Science, Queen Mary University of London, London E1 4NS, UK

Abstract

Imaging from optical coherence tomography (OCT) is widely used for detecting retinal diseases, localization of intra-retinal boundaries, etc. It is, however, degraded by speckle noise. Deep learning models can aid with denoising, allowing clinicians to clearly diagnose retinal diseases. Deep learning models can be considered as an end-to-end framework. We selected denoising studies that used deep learning models with retinal OCT imagery. Each study was quality-assessed through image quality metrics (including the peak signal-to-noise ratio—PSNR, contrast-to-noise ratio—CNR, and structural similarity index metric—SSIM). Meta-analysis could not be performed due to heterogeneity in the methods of the studies and measurements of their performance. Multiple databases (including Medline via PubMed, Google Scholar, Scopus, Embase) and a repository (ArXiv) were screened for publications published after 2010, without any limitation on language. From the 95 potential studies identified, a total of 41 were evaluated thoroughly. Fifty-four of these studies were excluded after full text assessment depending on whether deep learning (DL) was utilized or the dataset and results were not effectively explained. Numerous types of OCT images are mentioned in this review consisting of public retinal image datasets utilized purposefully for denoising OCT images (n = 37) and the Optic Nerve Head (ONH) (n = 4). A wide range of image quality metrics was used; PSNR and SNR that ranged between 8 and 156 dB. The minority of studies (n = 8) showed a low risk of bias in all domains. Studies utilizing ONH images produced either a PSNR or SNR value varying from 8.1 to 25.7 dB, and that of public retinal datasets was 26.4 to 158.6 dB. Further analysis on denoising models was not possible due to discrepancies in reporting that did not allow useful pooling. An increasing number of studies have investigated denoising retinal OCT images using deep learning, with a range of architectures being implemented. The reported increase in image quality metrics seems promising, while study and reporting quality are currently low.

Publisher

MDPI AG

Reference65 articles.

1. Aumann, S., Donner, S., Fischer, J., and Müller, F. (2019). High Resolution Imaging in Microscopy and Ophthalmology, Springer International Publishing.

2. BM3D-based total variation algorithm for speckle removal with structure-preserving in OCT images;Huang;Appl. Opt.,2019

3. Optical coherence tomography angiography in diabetic retinopathy: A review of current applications;Tey;Eye Vis.,2019

4. Reliability of Retinal Pathology Quantification in Age-Related Macular Degeneration: Implications for Clinical Trials and Machine Learning Applications;Liefers;Transl. Vis. Sci. Technol.,2021

5. Deep learning in neural networks: An overview;Schmidhuber;Neural Netw.,2015

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3