Accuracy and Efficacy of Artificial Intelligence-Derived Automatic Measurements of Transthoracic Echocardiography in Routine Clinical Practice

Author:

Shiokawa Noriko1,Izumo Masaki2ORCID,Shimamura Toshio1,Kurosaka Yui1,Sato Yukio2,Okamura Takanori1,Akashi Yoshihiro Johnny2ORCID

Affiliation:

1. Ultrasound Center, St. Marianna University Hospital, 2-16-1 Sugao, Miyamae-ku, Kawasaki 216-8511, Japan

2. Department of Cardiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki 216-8511, Japan

Abstract

Background: Transthoracic echocardiography (TTE) is the gold standard modality for evaluating cardiac morphology, function, and hemodynamics in clinical practice. While artificial intelligence (AI) is expected to contribute to improved accuracy and is being applied clinically, its impact on daily clinical practice has not been fully evaluated. Methods: We retrospectively examined 30 consecutive patients who underwent AI-equipped TTE at a single institution. All patients underwent manual and automatic measurements of TTE parameters using the AI-equipped TTE. Measurements were performed by three sonographers with varying experience levels: beginner, intermediate, and expert. Results: A comparison between the manual and automatic measurements assessed by the experts showed extremely high agreement in the left ventricular (LV) filling velocities (E wave: r = 0.998, A wave: r = 0.996; both p < 0.001). The automated measurements of LV end-diastolic and end-systolic diameters were slightly smaller (−2.41 mm and −1.19 mm) than the manual measurements, although without significant differences, and both methods showing high agreement (r = 0.942 and 0.977, both p < 0.001). However, LV wall thickness showed low agreement between the automated and manual measurements (septum: r = 0.670, posterior: r = 0.561; both p < 0.01), with automated measurements tending to be larger. Regarding interobserver variabilities, statistically significant agreement was observed among the measurements of expert, intermediate, and beginner sonographers for all the measurements. In terms of measurement time, automatic measurement significantly reduced measurement time compared to manual measurement (p < 0.001). Conclusions: This preliminary study confirms the accuracy and efficacy of AI-equipped TTE in routine clinical practice. A multicenter study with a larger sample size is warranted.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3