Validation of Adapted Neutralization Assays Developed to Discriminate Anti-Rabies Virus Activity of Two Different Anti-Rabies Virus Monoclonal Antibodies Administered as a Combination

Author:

Companjen Arjen12,Moore Susan3ORCID,Boulanger Bruno4,Kostense Stefan15,Marissen Wilfred16

Affiliation:

1. Crucell Holland B.V., Archimedesweg 4-6, 2333 CN Leiden, The Netherlands

2. LMBA, Poggenbeekstraat 28, 6813 KH Arnhem, The Netherlands

3. Kansas State Veterinary Diagnostic Laboratory, Manhattan, KS 66506, USA

4. PharmaLex, 1435 Mont-Saint-Guibert, Belgium

5. Charles River Laboratories, 2333 CR Leiden, The Netherlands

6. Merus N.V., Uppsalalaan 17, 3584 CT Utrecht, The Netherlands

Abstract

Assessment of rabies virus (RABV) neutralizing antibodies in subjects vaccinated or injected with anti-RABV immunoglobulins is central in determination of rabies protection. The rapid fluorescent focus inhibition test (RFFIT) is used for assessment of anti-RABV activity in serum. The current anti-RABV polyclonal preparations on the market pose difficulties in production and vary in quality. RABV neutralizing monoclonal antibodies (MAbs) are being evaluated as replacements. Different anti-RABV MAbs may neutralize different RABV isolates, thus two or more MAbs directed against different epitopes on the RABV glycoprotein are needed. It is therefore important to ensure neutralizing activity against all RABV isolates in sera of subjects injected with an anti-RABV MAb product consisting of two or more MAbs. The RFFIT, utilizing CVS-11 as challenge virus, cannot discriminate between the activities of different anti-RABV MAbs. We developed and validated two RFFIT methods enabling specific assessment of two different anti-RABV MAbs (CR57 and CR4098) in using two mutant CVS-11 strains resistant to either CR57 or CR4098 neutralization. The validation results demonstrate that both RFFIT assays using MAb resistant RABV are precise, accurate, linear, specific, and stable within the linear range of 0.025 IU/mL to 1.0 IU/mL. This method design can, therefore, be used to determine MAb specific anti-RABV activity in human serum samples.

Publisher

MDPI AG

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3