Detecting Pre-Analytically Delayed Blood Samples for Laboratory Diagnostics Using Raman Spectroscopy

Author:

Hunold Pascal12ORCID,Fischer Markus2,Olthoff Carsten12,Hildebrand Peter W.2,Kaiser Thorsten13ORCID,Staritzbichler René2ORCID

Affiliation:

1. Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, University Hospital Leipzig, 04103 Leipzig, Germany

2. Institute for Medical Physics and Biophysics, Leipzig University, 04107 Leipzig, Germany

3. University Institute for Laboratory Medicine, Microbiology and Clinical Pathobiochemistry, University Hospital OWL of Bielefeld University, Campus Klinikum Lippe, 32756 Detmold, Germany

Abstract

In this proof-of-principle study, we systematically studied the potential of Raman spectroscopy for detecting pre-analytical delays in blood serum samples. Spectra from 330 samples from a liver cirrhosis cohort were acquired over the course of eight days, stored one day at room temperature, and stored subsequently at 4 °C. The spectra were then used to train Convolutional Neural Networks (CNN) to predict the delay to sample examination. We achieved 90% accuracy for binary classification of the serum samples in the groups “without delay” versus “delayed”. Spectra recorded on the first day could be distinguished clearly from all subsequent measurements. Distinguishing between spectra taken in the range from the second to the last day seems to be possible as well, but currently, with an accuracy of approximately 70% only. Importantly, filtering out the fluorescent background significantly reduces the precision of detection.

Funder

Open Access Publishing Fund of Leipzig University

Publisher

MDPI AG

Subject

Inorganic Chemistry,Organic Chemistry,Physical and Theoretical Chemistry,Computer Science Applications,Spectroscopy,Molecular Biology,General Medicine,Catalysis

Reference25 articles.

1. (2017). REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017 on medical devices, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directives 90/385/EEC and 93/42/EEC. Off. J. Eur. Union, L117, 1–175.

2. Evaluation of the short-term stability of specimens for clinical laboratory testing;Ikeda;Biopreserv. Biobank.,2015

3. Impact of different storage times at room temperature of unspun citrated blood samples on routine coagulation tests results. Results of a bicenter study and review of the literature;Toulon;Int. J. Lab. Hematol.,2017

4. Preanalytical variables and off-site blood collection: Influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy;Mulder;Clin. Chem.,2005

5. Errors in a stat laboratory: Types and frequencies 10 years later;Carraro;Clin. Chem.,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3